DTC B2973


B3E090201072W50

DTC B2973

Running light relay circuit failure

DETECTION CONDITION

Short to power supply or GND in PJB internal circuit between microcomputer and running light relay

POSSIBLE CAUSE

• Running light relay malfunction
• PJB malfunction

Diagnostic procedure

STEP

INSPECTION

ACTION

1
INSPECT DTC
• Clear the DTC from the PJB memory using the WDS or equivalent.
• Perform the self-test.
(See PJB SELF-TEST.)
• Is the same DTC present?
Yes
Go to the next step.
No
Troubleshooting completed.
2
INSPECT RUNNING LIGHT RELAY
• Inspect the running light relay.
• Is there any malfunction?
Yes
Replace the running light relay, then go to the next step.
No
Go to the next step.
3
VERIFY TROUBLESHOOTING COMPLETED
• Make sure to reconnect all disconnected connectors.
• Clear the DTC from the PJB memory using the WDS or equivalent.
• Perform the self-test.
(See PJB SELF-TEST.)
• Is the same DTC present?
Yes
Replace the PJB.
No