INHIBITOR SWITCH AND CONTROL CABLE ADJUSTMENT
2018 / ECLIPSE CROSS / EC - Workshop Manual
23 -AUTOMATIC TRANSMISSION > 23A-CVT > ON-VEHICLE SERVICE > ESSENTIAL SERVICE > INHIBITOR SWITCH AND CONTROL CABLE ADJUSTMENT
1. Move the selector lever to the "N" range.
cautionBe careful not to deform the manual control lever when disconnecting the transmission control cable. Also, do not overdo it with a slotted screwdriver etc.
 
2. Insert the special tool MB 992277 or a commercially available clip remover in the illustrated section between the transmission control cable and the manual control lever, and press down the tool in the direction of the arrow pressing it against the pin, and disconnect the transmission control cable by using leverage.
3. Move the manual control lever to neutral position.
 
4. Align the hole at the end of the manual control lever and the hole in the inhibitor switch body flange (section A - A).
noteInsert a Φ5 bar into the aligned holes in the inhibitor switch body flange and on the tip of the manual control lever to position the inhibitor switch body.
 
5. Attach the transmission control cable to the manual control lever.
6. Make sure that the selector lever is in the "N" range.
7. Make sure that the transmission side ranges that are corresponding to the selector lever position operate and function without fail.