STEP 2. Measure the output wave pattern of the select pressure solenoid valve at CVT-ECU connector (LBLS terminal).
(1) Connect the CVT assembly connector.
(2) Engine: Idling
(3) When the vehicle is stationary
(4) Selector lever position: N
(5) Connect an oscilloscope, and measure the voltage between CVT-ECU connector LBLS terminal and body earth.OK: A wave pattern such as the one shown on
(Check Procedure Using an Oscilloscope) should be output. There should be no noise in the output wave pattern. Is the check result normal?
Go to Step 3.
Refer to diagnosis code No.P2720: Malfunction of Select Pressure Solenoid Valve (short)
, or diagnosis code No.P2721: Malfunction of Select Pressure Solenoid Valve (open)
.