35 -SERVICE BRAKES > 35C-ACTIVE STABILITY CONTROL SYSTEM (ASC) > ON-VEHICLE SERVICE > G AND YAW RATE SENSOR CALIBRATION
| caution | Before performing calibration, check that the G and yaw rate sensor-related diagnosis code is not set. |
| caution | After the next operation has been completed, carry out the calibration to make ASC-ECU learn the neutral position of the G and yaw rate sensor. |
1. Park the vehicle on a level surface.
2. | caution | Before connecting or disconnecting M.U.T.-IIISE, always turn the ignition switch to the "LOCK" (OFF) position. |
Before setting M.U.T.-IIISE, turn the ignition key to the "LOCK" (OFF) position.
3. Turn the ignition switch to the "ON" position.
4. Select "ABS/ASC/ASTC/WSS."
5. Select "Special function."
6. Select "Sensor calibration."
7. Select "Lateral G sensor calibration."
8. Select "G sensor calibration."
9. Before removing M.U.T.-IIISE from the vehicle, turn the ignition key to the "LOCK" (OFF) position.