STEP 1. Check the stop lamp switch.
STEP 2. M.U.T.-IIISE actuator test
STEP 3. Check of short to power supply, short to earth, and open circuit in STLD line between ASC-ECU connector and ETACS-ECU connector
Is the check result normal?
Go to Step 4.
Repair the connector(s) or wiring harness.
STEP 4. Check of short to power supply, short to earth, and open circuit in STP line between ASC-ECU connector and stop lamp connector
Is the check result normal?
Go to Step 5.
Repair the connector(s) or wiring harness.
STEP 5. Check whether the diagnosis code is set again.
(1) Erase the diagnosis code.
(2) Ignition switch "LOCK" (OFF)
(3) Ignition switch "ON"
Is diagnosis code No.C1801 set?
Replace the hydraulic unit (integrated with ASC-ECU) (Refer to
).
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/How to Cope with Intermittent Malfunctions
).