42 -BODY > 42B-KEYLESS OPERATION SYSTEM (KOS) > TROUBLESHOOTING > DIAGNOSIS CODE PROCEDURES > B1156 Power supply voltage fail
Code No.B1156 Power supply voltage low
caution
When replacing the ECU, always check that the communication circuit is normal.
DIAGNOSTIC FUNCTION
If the system detects that +B1 voltage decreases, the KOS&OSS-ECU will set diagnosis code No. B1156.
JUDGEMENT CRITERIA
Check Conditions
While the KOS&OSS-ECU is waking up and is not cranking.
Judgement Criterion
+B voltage remains 9.0 V or less for at least five seconds.
PROBABLE CAUSES
Damaged wiring harness or connector (+B line short to earth or open circuit)
Malfunction of KOS&OSS-ECU
Deteriorated battery
DIAGNOSIS PROCEDURE
note
Prior to diagnosis, check the battery (Refer to GROUP 54A - Battery - Battery Test ).
STEP 1. Voltage measurement at +B1 connector (+B1 line)
(1) Disconnect the connector, and measure at the wiring harness side.
(2) Turn the power supply mode of the engine switch from "ON" to "OFF".
(3) Measure the voltage between the +B connector (+B1 line) and the body earth.
OK: System voltage
Is the check result normal?
Go to Step 3.
Go to Step 2.
STEP 2. Check of short to earth or open circuit in +B1 line between the KOS&OSS-ECU connector and the battery.
Is the check result normal?
Go to Step 3.
Repair the connector(s) or wiring harness.
STEP 3. Check whether the diagnosis code is set again.
Is the diagnosis code set?
Replace the KOS&OSS-ECU and register the ID code (Refer to ).
Intermittent malfunction is suspected (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunction ).