STEP 1. M.U.T.-IIISE other system data list.
Check the ETACS-ECU input signal of ACC relay.- Turn the ignition switch to the "ACC" position.
| | | Item No. | Item name | Normal condition | | 111 | ACC switch | ON |
|
OK: Normal condition is displayed.
Is the check result normal?
Go to Step 2.
Refer to ETACS - Inspection Procedure 1 "The ignition switch (ACC) signal is not sent to the ETACS-ECU
."
STEP 2. Check the DC/DC converter.
Check the continuity of the DC/DC converter.Is the check result normal?
Go to Step 3.
Replace the DC/DC converter.
STEP 3. Voltage measurement at DC/DC converter connector (IGN terminal).
(1) Disconnect the connector, and measure at the wiring harness side.
(2) Turn the ignition switch to the "ACC" position.
(3) Check the voltage between DC/DC converter connector (IGN terminal) and body earth.OK: System voltage
Is the check result normal?
Go to Step 5.
Go to Step 4.
STEP 4. Check of short to power supply, short to earth, and open circuit in IGN line between DC/DC converter connector and ETACS-ECU connector.
STEP 5. Voltage measurement at DC/DC converter connector (PWR terminal).
(1) Disconnect the connector, and measure at the wiring harness side.
(2) Check the voltage between DC/DC converter connector (PWR terminal) and body earth.OK: System voltage
Is the check result normal?
Go to Step 7.
Go to Step 6.
STEP 6. Check of short to earth, and open circuit in PWR line between fusible link and DC/DC converter connector.
STEP 7. Check of short to power supply, short to earth, and open circuit in OUT1 and OUT2 line between DC/DC converter connector and multivision display connector.
Is the check result normal?
Go to Step 8.
Repair the connector(s) or wiring harness.
STEP 8. Resistance measurement at multivision display connector (GND terminal).
(1) Disconnect the connector, and measure at the wiring harness side.
(2) Check the continuity between the multivision display connector (GND terminal) and body earth.OK: Continuity exists (2 Ω or less)
Is the check result normal?
Go to Step 10.
Go to Step 9.
STEP 9. Check of open circuit in GND line between multivision display connector and body earth.
STEP 10. Retest the system.