Description

 
 SYSTEM DESCRIPTION

Sensor
Input signal to ECM
ECM function
Actuator
Camshaft position sensor (PHASE)
Crankshaft position sensor (POS)
Engine speed
Heated oxygen sensor 2 heater control
Heated oxygen sensor 2 heater
Engine coolant temperature sensor
Engine coolant temperature
Mass air flow sensor
Amount of intake air

The ECM performs ON/OFF control of the heated oxygen sensor 2 heater corresponding to the engine speed, amount of intake air and engine coolant temperature.
 
 OPERATION

Engine speed
Heated oxygen sensor 2 heater
Above 3,600 rpm
OFF
Below 3,600 rpm after the following conditions are met.
  • Engine: After warming up
  • Keeping the engine speed between 3,500 and 4,000 rpm for 1 minute and at idle for 1 minute under no load
ON

DTC Logic

 
 DTC DETECTION LOGIC

DTC No.
Trouble diagnosis name
DTC detecting condition
Possible cause
P0037
Heated oxygen sensor 2 heater (bank 1) control circuit low
The current amperage in the heated oxygen sensor 2 heater circuit is out of the normal range.
(An excessively low voltage signal is sent to ECM through the heated oxygen sensor 2 heater.)
  • Harness or connectors
    (The heated oxygen sensor 2 heater circuit is open or shorted.)
  • Heated oxygen sensor 2 heater
P0038
Heated oxygen sensor 2 heater (bank 1) control circuit high
The current amperage in the heated oxygen sensor 2 heater circuit is out of the normal range.
(An excessively high voltage signal is sent to ECM through the heated oxygen sensor 2 heater.)
  • Harness or connectors
    (The heated oxygen sensor 2 heater circuit is shorted.)
  • Heated oxygen sensor 2 heater
P0057
Heated oxygen sensor 2 heater (bank 2) control circuit low
The current amperage in the heated oxygen sensor 2 heater circuit is out of the normal range.
(An excessively low voltage signal is sent to ECM through the heated oxygen sensor 2 heater.)
  • Harness or connectors
    (The heated oxygen sensor 2 heater circuit is open or shorted.)
  • Heated oxygen sensor 2 heater
P0058
Heated oxygen sensor 2 heater (bank 2) control circuit high
The current amperage in the heated oxygen sensor 2 heater circuit is out of the normal range.
(An excessively high voltage signal is sent to ECM through the heated oxygen sensor 2 heater.)
  • Harness or connectors
    (The heated oxygen sensor 2 heater circuit is shorted.)
  • Heated oxygen sensor 2 heater

 
 DTC CONFIRMATION PROCEDURE

 
 1.PRECONDITIONING
 
 2.PERFORM DTC CONFIRMATION PROCEDURE

Diagnosis Procedure


 
 1.CHECK GROUND CONNECTION
 
 2.CHECK HO2S2 POWER SUPPLY CIRCUIT
 
 3.DETECT MALFUNCTIONING PART
 
 4.CHECK HO2S2 OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
 
 5.CHECK HEATED OXYGEN SENSOR 2 HEATER
 
 6.REPLACE HEATED OXYGEN SENSOR 2
 
 7.CHECK INTERMITTENT INCIDENT

Component Inspection


 
 1.CHECK HEATED OXYGEN SENSOR 2 HEATER
 
 2.REPLACE HEATED OXYGEN SENSOR 2