P2440, P2442 AIR CUT SOLENOID VALVE
VR38
P2440 P2442
- Description
- DTC Logic
- Diagnosis Procedure
- Component Inspection (AIR CUT SOLENOID VALVE RELAY)
- Component Inspection (AIR CUT SOLENOID VALVE)
Description
The air cut solenoid valve is installed in the rear of the cylinder head and opens or closes the passage of the secondary air to the engine exhaust port. When activating the air pump, the ECM turns the air cut solenoid valve ON and opens the valve so that the air is supplied to the exhaust port. The ECM turns the air cut solenoid valve OFF and closes the valve to prevent air blow back. Then the ECM deactivates the air pump. The ECM does not activate the air cut solenoid valve directly. The ECM controls the air cut solenoid valve by turning the air cut solenoid valve relay ON/OFF.
DTC Logic
DTC DETECTION LOGIC|
DTC No. |
Trouble diagnosis name |
DTC detecting condition |
Possible cause |
|
P2440 |
Air cut solenoid valve (bnak1) stuck open |
|
|
|
P2442 |
Air cut solenoid valve (bnak2) stuck open |
|
DTC CONFIRMATION PROCEDURE
1.CHECK SECONDARY AIR INJECTION SYSTEM MASS AIR FLOW SENSOR