DIAGNOSIS SYSTEM (HVAC)
AUTOMATIC AIR CONDITIONER
CONSULT-III performs the following functions via CAN communication with A/C auto amp.
| Diagnostic mode | Description |
| Self diagnostic result | Displays the diagnosis results judged by A/C auto amp. |
| Data monitor | Displays the input/output signal of A/C auto amp. |
| Active test | The signals used to activate each device are forcibly supplied from A/C auto amp. |
| Work support | Changes the setting for each setting function.
|
| ECU identification | Displays the part number of A/C auto amp. |
NOTE:
Diagnosis should be performed with engine running. Door motor operation speeds become slower and NO results may be returned even for normal operation if battery voltage drops below 12 V during self-diagnosis.
SELF-DIAGNOSIS RESULTSRefer to DTC Index.
Display Item List
| DTC | Items (CONSULT‐III screen terms) | Diagnostic item is detected when... | Possible cause |
| U1000 | CAN COMM CIRCUIT | When A/C auto amp. is not transmitting or receiving CAN communication signal for 2 or more seconds. | CAN communication system |
| U1010 | CONTROL UNIT (CAN) | When detecting error during the initial diagnosis of CAN controller of A/C auto amp. | A/C auto amp. |
| B257B | AMB TEMP SEN (SHORT) | The ambient sensor recognition temperature is too high. |
|
| B257C | AMB TEMP SEN (OPEN) | The ambient sensor recognition temperature is too low. |
|
| B2578 | IN CAR SENSOR (OUT OF RANGE [LOW]) | The in-vehicle sensor recognition temperature is too high. |
|
| B2579 | IN CAR SENSOR (OUT OF RANGE [HI]) | The in-vehicle sensor recognition temperature is too low. |
|
| B2581 | EVAP TEMP SEN (SHORT) | The intake sensor recognition temperature is too high. |
|
| B2582 | EVAP TEMP SEN (OPEN) | The intake sensor recognition temperature is too low. |
|
| B2630* | SUNLOAD SEN (SHORT) | Detected calorie at sunload sensor 2832 w/m2 (2437 kcal/m2·h) or more |
|
| B2631* | SUNLOAD SEN (OPEN) | Detected calorie at sunload sensor 64.7 w/m2 (56 kcal/m2·h) or less |
|
| B2632 | DR AIRMIX ACTR (SHORT) | Air mix door PBR (driver side) position 95% or more |
|
| B2633 | DR AIRMIX ACTR (OPEN) | Air mix door PBR (driver side) position 5% or less |
|
| B2634 | PASS AIRMIX ACTR (SHORT) | Air mix door PBR (passenger side) position 95% or more |
|
| B2635 | PASS AIRMIX ACTR (OPEN) | Air mix door PBR (passenger side) position 5% or less |
|
| B2636 | DR VENT DOOR FAIL | When the malfunctioning door position is detected at VENT position |
|
| B2637 | DR B/L DOOR FAIL | When the malfunctioning door position is detected at B/L position | |
| B2638 | DR D/F1 DOOR FAIL | When the malfunctioning door position is detected at FOOT position | |
| B2639 | DR DEF DOOR FAIL | When the malfunctioning door position is detected at DEF position | |
| B2654 | D/F2 DOOR FAIL | When the malfunctioning door position is detected at D/F position | |
| B2655 | B/L2 DOOR FAIL | When the malfunctioning door position is detected at B/L2 position | |
| B263D | FRE DOOR FAIL | When the malfunctioning intake door position is detected at FRE position |
|
| B263E | 20P FRE DOOR FAIL | When the malfunctioning intake door position is detected at 20%FRE position | |
| B263F | REC DOOR FAIL | When the malfunctioning intake door position is detected at REC position | |
| B2656 | BTC FRE DOOR FAIL | When the malfunctioning intake door position is detected |
DATA MONITORDisplay item list
| Monitor item [Unit] | Description | |
| COMP REQ SIG | [On/Off] | Displays A/C switch ON/OFF status transmitted to other units via CAN communication |
| FAN REQ SIG | [On/Off] | Displays fan switch ON/OFF status transmitted to other units via CAN communication |
| AMB TEMP SEN | [°C] | Ambient sensor value converted from ambient sensor signal received from ambient sensor |
| IN‐VEH TEMP | [°C] | In-vehicle sensor value converted from in-vehicle sensor signal received from in-vehicle sensor |
| INT TEMP SEN | [°C] | Intake sensor value converted from intake sensor signal received from intake sensor |
| SUNLOAD SEN | [w/m2] | Sunload sensor value converted from sunload sensor signal received from sunload sensor |
| AMB SEN CAL | [°C] | Ambient sensor value calculated by A/C auto amp. |
| IN‐VEH CAL | [°C] | In-vehicle sensor value calculated by A/C auto amp. |
| INT TEMP CAL | [°C] | Intake sensor value calculated by A/C auto amp. |
| SUNL SEN CAL | [w/m2] | Sunload sensor value calculated by A/C auto amp. |
| FAN DUTY | [%] | Duty ratio of blower motor judged by A/C auto amp. |
| XM | Target discharge air temperature judged by A/C auto amp. according to the temperature setting and the value from each sensor | |
| ENG COOL TEMP | [°C] | Water temperature signal value received from ECM via CAN communication |
| VEHICLE SPEED | [Mph (km/h)] | Vehicle speed signal value received from meter via CAN communication |
ACTIVE TEST| Test item | Description |
| Check each output device | The operation check of air conditioner system can be performed by selecting the mode. Refer to the following table for the conditions of each mode. |
Check each output device| Test item | |||||||
| MODE 1 | MODE 2 | MODE 3 | MODE 4 | MODE 5 | MODE 6 | MODE 7 | |
| Mode door position | VENT | B/L 1 | B/L 2 | FOOT | D/F | DEF | — |
| Intake door position | REC | REC | 20% FRE | FRE | FRE | FRE | — |
| Air mix door position (driver & passenger side) | FULL COLD | FULL COLD | FULL HOT | FULL HOT | FULL HOT | FULL HOT | — |
| Blower motor control signal duty ratio | 37% | 91% | 65% | 65% | 65% | 91% | — |
| Compressor (magnetic clutch) | ON | ON | OFF | OFF | ON | ON | — |
| Electronic control valve (ECV) duty ratio | 100% | 100% | 0% | 0% | 50% | 100% | — |
NOTE:
- Perform the inspection of each output device after starting the engine because the compressor is operated.
- If the Mode 7 is selected, the malfunction is displayed but it is normal.
WORK SUPPORT| Work item | Description | Refer to |
| TEMP SET CORRECT (Temperature setting trimmer) | If the temperature felt by the customer is different than the air flow temperature controlled by the temperature setting, the A/C auto amp. control temperature can be adjusted to compensate for the temperature setting. | Temperature Setting Trimmer |
| FRE MEMORY SET [Inlet port memory function (FRE)] |
| Inlet Port Memory Function (FRE) |
| REC MEMORY SET [Inlet port memory function (REC)] |
| Inlet Port Memory Function (REC) |
| BLOWER SET (Foot position setting trimmer) | In FOOT mode, the air blowing to DEF can change ON/OFF. | Foot Position Setting Trimmer |
NOTE:
When the battery cable is disconnected from the negative terminal or when the battery voltage becomes 10 V or less, the setting of WORK SUPPORT may be cancelled.