INTERIOR ROOM LAMP POWER SUPPLY CIRCUIT
Description
Component Function Check
Diagnosis Procedure
Description
Provides the interior room lamp power supply. Also cuts the power supply when the interior room lamp battery saver activating.
Component Function Check
1.CHECK INTERIOR ROOM LAMP POWER SUPPLY FUNCTION
CONSULT-III ACTIVE TEST
Turn ignition switch ON.
Turn each interior room lamp ON.
Map lamp
Step lamp
Vanity mirror lamp
Trunk room lamp
Select "BATTERY SAVER" of BCM (BATTERY SAVER) active test item.
With operating the test items, check that each interior room lamps operation.
Off
: Interior room lamp OFF
On
: Interior room lamp ON
Are the interior room lamps turned ON/OFF?
YES
>>
Interior room lamp power supply circuit is normal.
NO
>>
Refer to
Diagnosis Procedure
.
Diagnosis Procedure
1.CHECK INTERIOR ROOM LAMP POWER SUPPLY OUTPUT
CONSULT-III ACTIVE TEST
Turn ignition switch ON.
Select “BATTERY SAVER” of BCM (BATTERY SAVER) active test item.
With operating the test item, check voltage between BCM harness connector and ground.
Terminals
Test item
Voltage
(Approx.)
(+)
(-)
BCM
Ground
BATTERY SAVER
Connector
Terminal
M119
4
Off
0 V
On
Battery voltage
Is the measurement value normal?
YES
>>
GO TO 2
.
NO
>>
Replace BCM.
2.CHECK INTERIOR ROOM LAMP POWER SUPPLY OPEN CIRCUIT
Turn ignition switch OFF.
Disconnect the following connectors.
Map lamp
Vanity mirror lamp (LH)
Vanity mirror lamp (RH)
Trunk room lamp
Step lamp (driver side)
Step lamp (passenger side)
Check continuity between BCM harness connector and each interior room lamp harness connector.
BCM
Each interior room lamp
Continuity
Connector
Terminal
Connector
Terminal
M119
4
Map lamp
R6
1
Existed
Vanity mirror lamp (LH)
R2
2
Vanity mirror lamp (RH)
R3
2
Trunk room lamp
B42
1
Step lamp (driver side)
D23
1
Step lamp (passenger side)
D53
1
Does continuity exist?
YES
>>
GO TO 3
.
NO
>>
Repair the harnesses or connectors.
3.CHECK INTERIOR ROOM LAMP POWER SUPPLY SHORT CIRCUIT
Check continuity between BCM harness connector and ground.
BCM
Ground
Continuity
Connector
Terminal
M119
4
Not existed
Does continuity exist?
YES
>>
Repair the harnesses or connectors.
NO
>>
Check that each interior room lamp has no internal short circuit.