Check that the VDC OFF indicator lamp in the combination meter illuminates when pushing down the set-up switch (VDC) for approximately 1 second or more.
NO>>If there is an open or short in the harness, repair or replace the harness.
4.CHECK COMBINATION METER
Check that the VDC OFF indicator lamp in the combination meter illuminates when pushing down the set-up switch (VDC) for approximately 1 second or more.
Is the inspection result normal?
YES>>INSPECTION END
NO>>Repair or replace combination meter.
Component Inspection
1.CHECK SET-UP SWITCH (VDC)
Turn the ignition switch OFF.
Disconnect set-up switch (VDC) connector.
Check the continuity between set-up switch (VDC) connector terminals.