Nissan GT-R (R35) · Service Manual BRAKES

CALIBRATION OF DECEL G SENSOR

INSPECTION AND ADJUSTMENT · VDC/TCS/ABS

Description


When doing work that applies to the list below, make sure to calibrate decel G sensor before running vehicle.

×: Required –: Not required
Situation
Calibration of decel G sensor
Removing/Installing ABS actuator and electric unit (control unit)
×
Replacing ABS actuator and electric unit (control unit)
×
Removing/Installing steering components

Replacing steering components

Removing/Installing suspension components

Replacing suspension components

Changing old tires to new ones

Adjusting wheel alignment

Removing/Installing yaw rate/side/decel G sensor
×
Replacing yaw rate/side/decel G sensor
×

Special Repair Requirement

 
 CALIBRATION OF DECEL G SENSOR

■ CAUTION ■
  • To calibrate decel G sensor, always use CONSULT-III.
    (Calibration cannot be done without CONSULT-III)
  • Perform the G sensor calibration only with the vehicle parked on level surface.

 
 1.ALIGN THE VEHICLE STATUS
 
 2.PERFORM THE CALIBRATION OF DECEL G SENSOR
 
 3.CHECK DATA MONITOR
 
 4.ERASE THE SELF-DIAGNOSIS MEMORY