FAIL-SAFE FUNCTION

When a communication malfunction between A/C auto amp. and AV control unit and preset switch continued for approximately 30 seconds or more, control the air conditioner under the following conditions.

Compressor
: ON
Air outlet
: AUTO
Air inlet
: FRE (Fresh air intake)
Blower speed
: AUTO
Preset temperature
: Setting before communication malfunction
A/C display