REMOVAL & INSTALLATION

  1. Remove the air cleaner assembly from the carburetor.
  2. Remove the electrical lead which runs from the choke cap to the voltage regulator.
  3. Disconnect the setting piston from the auxiliary choke diaphragm.
  4. Remove the 3 screws which secure the choke cap to the carburetor and remove the cap.
  5. Be sure that the choke lever is positioned in the middle of the bi-metal before installing the cap.

    After installation, check to see that the carburetor choke valve closes when the cap is turned counterclockwise. Align the setting marks on the choke housing and cap. See the Carburetor Section for further choke adjustments.