Fuel Leakage Check Procedure
Precautions: Precautions for Fuel System Service · General safety (00)
After performing any service on fuel system, check that there is no fuel leakage as follows.
1)Set ignition “ON” for 3 seconds (to operate fuel pump) and then to “OFF”. Repeat this cycle of operation 3 or 4 times.
Fuel pressure should now be established in fuel system and felt by hand on fuel feed hose.
Fuel pressure should now be established in fuel system and felt by hand on fuel feed hose.
2)Check that there is no fuel leakage from any part of fuel system.