Cranking System Specifications
Precautions: General safety (00)
Non-ENG A-STOP model (MITSUBISHI 0.9 kW type)
| Voltage | 12 V | ||||
| Output | 0.9 kW | ||||
| Rating | 30 seconds | ||||
| Direction of rotation | Clockwise as viewed from pinion side | ||||
| Number of pinion teeth | 10 | ||||
| Performance | Voltage | Current | Torque | Revolution speed | |
| At around 20 °C (68 °F) | No-load characteristic | 11 V | 95 A MAX | — | 3,000 rpm MIN |
| Loaded characteristic | 7.5 V | 300 A | 7.3 N·m (0.74 kgf-m, 5.5 lbf-ft) MIN | 940 rpm MIN | |
| Locked characteristic | 4 V | 640 A MAX | 13 N·m (1.3 kgf-m, 9.5 lbf-ft) MIN | — | |
| Magnetic switch operating voltage | 8 volts MAX | ||||
ENG A-STOP model (MITSUBISHI 1.0 kW type)
| Voltage | 12 V | ||||
| Output | 1.0 kW | ||||
| Rating | 30 seconds | ||||
| Direction of rotation | Clockwise as viewed from pinion side | ||||
| Number of pinion teeth | 10 | ||||
| Performance | Voltage | Current | Torque | Revolution speed | |
| At around 20 °C (68 °F) | No-load characteristic | 11.0 V | 90 A MAX | — | 2,730 rpm MIN |
| Loaded characteristic | 7.5 V | 300 A | 11 N·m (1.1 kgf-m, 8.5 lbf-ft) MIN | 700 rpm MIN | |
| Locked characteristic | 4.0 V | 510 A MAX | 16 N·m (1.6 kgf-m, 12.0 lbf-ft) MIN | — | |
| Magnetic switch operating voltage | 8 volts MAX | ||||