7B HVAC System
› Non-A/C › Repair Instructions
Blower Motor Removal and Installation
Precautions:
General safety (00)
Removal
1)
Disconnect negative (–) cable at battery.
2)
Remove passenger side instrument panel undercover (1).
3)
Disconnect connector (1) and clamp (3) from blower motor (2).
4)
Remove screws (4).
5)
Remove blower motor from HVAC unit.
Installation
Reverse removal procedure.
← HVAC Unit Removal and Installation