Home › ENGINE · 2UZ-FE › ENGINE CONTROL SYSTEM › SFI SYSTEM

SFI SYSTEM > ECM Power Source Circuit

for Preparation Click here


DESCRIPTION

When the ignition switch is turned ON, the positive battery voltage is applied to terminal IGSW of the ECM and the EFI relay control circuit in the ECM sends a signal to terminal MREL of the ECM switching on the EFI relay.
This signal causes current to flow to the coil, closing the contacts of the EFI relay and supplying power to terminal +B of the ECM.
If the ignition switch is turned OFF, the ECM holds the EFI relay for a maximum of 2 seconds to allow for the initial setting of the throttle valve.

WIRING DIAGRAM


A130724E01


INSPECTION PROCEDURE

1.CHECK ECM (+B VOLTAGE)


    E118245E28
  1. Turn the ignition switch ON.

  1. Measure the voltage of the ECM connectors.

    Standard voltage:
    Tester Connection
    Specified Condition
    +B (E8-1) - E1 (E6-1)
    9 to 14 V



OK
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE
NG


2.CHECK HARNESS AND CONNECTOR (ECM - BODY GROUND)


    G035617E07
  1. Disconnect the E6 ECM connector.

  1. Measure the resistance of the wire harness side connector.

    Standard resistance:
    Tester Connection
    Specified Condition
    E1 (E6-1) - Body ground
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


3.CHECK ECM (IGSW VOLTAGE)


    E118245E29
  1. Turn the ignition switch ON.

  1. Measure the voltage of the ECM connectors.

    Standard voltage:
    Tester Connection
    Specified Condition
    IGSW (E8-9) - E1 (E6-1)
    9 to 14 V



NG
Go to step 6
NG


4.INSPECT FUSE (IGN)


    A072891E01
  1. Remove the IGN fuse from the instrument panel junction block RH.

  1. Measure the resistance of the IGN fuse.

    Standard resistance:
    Below 1 Ω



NG
REPLACE FUSE
OK


5.INSPECT IGNITION SWITCH ASSEMBLY


    A087913E10
  1. Remove the lower finish panel.

  1. Disconnect the I18 ignition switch connector.

  1. Measure the resistance of the ignition switch.

    Standard resistance:
    Switch position
    Tester Connection
    Specified Condition
    LOCK
    All Terminals
    10 kΩ or higher
    ACC
    2-3
    Below 1 Ω
    ON
    2-3, 2-4
    6-7
    START
    1-2, 2-4
    6-7, 6-8

  1. Reconnect the ignition switch connector.



NG
REPLACE IGNITION SWITCH ASSEMBLY
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR (BATTERY - IGNITION SWITCH, IGNITION SWITCH - ECM) 

6.CHECK ECM (MREL VOLTAGE)


    E118245E30
  1. Turn the ignition switch ON.

  1. Measure the voltage of the ECM connectors.

    Standard voltage:
    Tester Connection
    Specified Condition
    MREL (E8-8) - E1 (E6-1)
    9 to 14 V



NG
REPLACE ECM
OK


7.INSPECT FUSE (EFI)


    A072881E03
  1. Remove the EFI fuse from the engine room junction block.

  1. Measure the resistance of the EFI fuse.

    Standard resistance:
    Below 1 Ω



NG
REPLACE FUSE
OK


8.INSPECT EFI RELAY (Marking: EFI OR ECD)


    B016200E03
  1. Remove the EFI relay from the engine room junction block.

  1. Measure the resistance of the EFI relay.

    Standard resistance:
    Terminal Connection
    Specified Condition
    3 - 5
    10 kΩ or higher
    3 - 5
    Below 1 Ω
    (when battery voltage is applied to terminals 1 and 2)

  1. Reinstall EFI relay.



NG
REPLACE EFI RELAY
OK


9.CHECK HARNESS AND CONNECTOR (ECM - BODY GROUND)


    A115739E02
  1. Disconnect the E8 ECM connector.

  1. Measure the resistance between the wire harness side connector and body ground.

    Standard resistance:
    Tester Connection
    Specified Condition
    MREL (E8-8) - Body ground
    Below 1 Ω

  1. Reconnect the ECM connector.



OK
REPAIR OR REPLACE HARNESS OR CONNECTOR
NG

CHECK FOR INTERMITTENT PROBLEMS