AUTOMATIC TRANSMISSION SYSTEM (for 1GR-FE) > DATA LIST / ACTIVE TEST |
| DATA LIST |
Warm up the engine.
Turn the ignition switch OFF.
Connect the intelligent tester together with the CAN VIM (controller area network vehicle interface module) to the DLC3.
Turn the ignition switch to the ON position.
Turn on the tester.
Select the item "DIAGNOSIS / OBD/MOBD / ECT / DATA LIST".
According to the display on the tester, read the "DATA LIST".
| Item | Measurement Item/Range (display) | Normal Condition | Diagnostic Note |
| STOP LIGHT SW | Stop light switch Status/ON or OFF |
| - |
| PNP SW [NSW] | PNP switch Status/ON or OFF | Shift lever position is; P and N: ON Except P and N: OFF | When the shift lever position displayed on the Intelligent tester differs from the actual position, adjustment of the PNP switch or the shift cable may be incorrect.
|
| LOW | PNP switch Status/ON or OFF | Shift lever position is; L: ON Except L: OFF | ↑ |
| 2ND | PNP switch Status/ON or OFF | Shift lever position is; 2 and L: ON Except 2 and L: OFF | ↑ |
| 3RD | PNP SW Status/ON or OFF | Shift lever position is; 3: ON Except 3: OFF | ↑ |
| 4th/DRIVE | PNP SW Status/ON or OFF | Shift lever position is; 4: ON Except 4: OFF | ↑ |
| REVERSE | PNP switch Status/ON or OFF | Shift lever position is; R: ON Except R: OFF | ↑ |
| DRIVE | PNP switch Status/ON or OFF | Shift lever position is; D and 4: ON Except D and 4: OFF | ↑ |
| SHIFT | Actual Gear Position/1st, 2nd, 3rd, 4th or 5th | Shift lever position is;
| - |
| LOCK UP SOL | Lock Up Solenoid Status/ON or OFF |
| - |
| SOLENOID (SLT) | Shift Solenoid SLT Status/ON or OFF |
| - |
| SOLENOID (SLU) | Shift Solenoid SLU Status/ON or OFF |
| - |
| AT FLUID TEMP | ATF Temp. Sensor No. 1 Value/min.: -40°C (-40°F) max.: 215°C (419°F) |
| If the value is "-40°C (-40°F)" or "215°C (419°F)", ATF temp. sensor No. 1 circuit is opened or shorted. |
| AT FLUID TEMP 2 | ATF Temp. Sensor No.2 Value/min.: -40°C (-40°F) max.: 215°C (419°F) |
| If the value is "-40°C (-40°F)" or "215°C (419°F)", ATF temp. sensor No. 2 circuit is open or shorted. |
| SPD (SP2) | Output shaft Speed/min.: 0 km/h (0 mph) max.: 255 km/h (158 mph) | Vehicle stopped: 0 km/h (0 mph)
| - |
| SPD (NT) | Input Turbine Speed/display: 50 r/min |
| - |
| ACTIVE TEST |
Warm up the engine.
Turn the ignition switch off.
Connect the intelligent tester together with the CAN VIM (controller area network vehicle interface module) to the DLC3.
Turn the ignition switch to the ON position.
Push the "ON" button of the intelligent tester.
Select the item "DIAGNOSIS / OBD/MOBD / ECT / ACTIVE TEST".
According to the display on tester, perform the "ACTIVE TEST".
| Item | Test Details | Diagnostic Note |
| SHIFT | [Test Details] Operate the shift solenoid valve and set the each shift position by yourself. [Vehicle Condition]
| Possible to check the operation of the shift solenoid valves. |
| LOCK UP | [Test Details] Control the shift solenoid SLU to set the automatic transmission to the lock-up condition. [Vehicle Condition]
| Possible to check the SLU operation. |
| LINE PRESS UP * | [Test Details] Operate the shift solenoid SLT and raise the line pressure. [Vehicle Condition]
OFF: Line pressure up (When the active test of "Control the Line Pressure Up" is performed, the ECM commands the SLT solenoid to turn off). ON: No action (normal operation) | - |