Home › TRANSMISSION · A750F AUTOMATIC TRANSMISSION › AUTOMATIC TRANSMISSION SYSTEM (for 2UZ-FE)

DTC    P0710    Transmission Fluid Temperature Sensor "A" Circuit

DTC    P0712    Transmission Fluid Temperature Sensor "A" Circuit Low Input

DTC    P0713    Transmission Fluid Temperature Sensor "A" Circuit High Input

for Preparation Click here


DESCRIPTION

The ATF (Automatic Transmission Fluid) temperature sensor converts the fluid temperature into a resistance value which is input into the ECM.
G031389E04
The ECM applies a voltage to the temperature sensor through ECM terminal THO1.
The sensor resistance changes with the transmission fluid temperature. As the temperature becomes higher, the sensor resistance decreases.
One terminal of the sensor is grounded so that the sensor resistance decreases and the voltage goes down as the temperature becomes higher.
The ECM calculates the fluid temperature based on the voltage signal.

DTC No.
DTC Detection Condition
Trouble Area
P0710
(a) and (b) are detected momentarily within 0.5 sec. when neither P0712 nor P0713 is detected (1-trip detection logic)
(a) ATF temperature sensor No. 1 resistance is less than 79 Ω.
(b) ATF temperature sensor No. 1 resistance is more than 156 kΩ.

HINT:
Within 0.5 sec., the malfunction switches from (a) to (b) or from (b) to (a)

  1. Open or short in ATF temperature sensor No. 1 circuit
  2. Transmission wire (ATF temperature sensor No. 1)
  3. ECM
P0712
ATF temperature sensor No. 1 resistance is less than 79 Ω for 0.5 sec. or more (1-trip detection logic)
  1. Short in ATF temperature sensor No. 1 circuit
  2. Transmission wire (ATF temperature sensor No. 1)
  3. ECM
P0713
ATF temperature No. 1 sensor resistance is more than 156 kΩ when 15 minutes or more have elapsed after the engine start DTC is detected for 0.5 sec. or more (1-trip detection logic)
  1. Open in ATF temperature sensor No. 1 circuit
  2. Transmission wire (ATF temperature sensor No. 1)
  3. ECM

MONITOR DESCRIPTION

These DTCs indicate an open or short in the automatic transmission fluid (ATF) temperature sensor (TFT sensor) circuit. The automatic transmission fluid (ATF) temperature sensor converts ATF temperature to an electrical resistance value. Based on the resistance, the ECM determines the ATF temperature, and the ECM detects an open or short in the ATF temperature circuit. If the resistance value of the ATF temperature is less than 79 Ω*1 or more than 156 kΩ*2, the ECM interprets this as a fault in the ATF sensor or wiring. The ECM will turn on the MIL and store the DTC.
*1: 150°C (302°F) or more is indicated regardless of the actual ATF temperature.
*2: -40°C (-40°F) is indicated regardless of the actual ATF temperature.

HINT:
The ATF temperature can be checked on the intelligent tester display.


MONITOR STRATEGY


Related DTCs
P0710: ATF temperature sensor/Range check (Chattering)
P0712: ATF temperature sensor/Range check (Low resistance)
P0713: ATF temperature sensor/Range check (High resistance)
Required sensors/Components
ATF temperature sensor (TFT sensor)
Frequency of operation
Continuous
Duration
0.5 sec.
MIL operation
Immediately
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


Range check (Chattering)
P0710: 
The monitor will run whenever this DTC is not present.
None
The typical enabling condition is not available.
-

Range check (Low resistance)
P0712: 
The monitor will run whenever this DTC is not present.
None
The typical enabling condition is not available.
-

Range check (High resistance)
P0713: 
The monitor will run whenever this DTC is not present.
None
Time after engine start
15 min. or more

TYPICAL MALFUNCTION THRESHOLDS


Range check (Chattering)
P0710: 
TFT (transmission fluid temperature) sensor resistance
Less than 79 Ω or more than 156 kΩ

Range check (Low resistance)
P0712: 
TFT sensor resistance.
Less than 79 Ω

Range check (High resistance)
P0713: 
TFT sensor resistance.
More than 156 kΩ

COMPONENT OPERATING RANGE


TFT sensor.
Atmospheric temperature to approx. 130°C (266°F)

WIRING DIAGRAM


G036787E01


INSPECTION PROCEDURE


DATA LIST

HINT:
According to the DATA LIST displayed by the intelligent tester, you can read the value of the switch, sensor, actuator and so on without parts removal. Reading the DATA LIST as the first step of troubleshooting is one method to shorten labor time.

NOTICE:
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

  1. Warm up the engine.

  2. Turn the ignition switch off.

  3. Connect the intelligent tester together with the CAN VIM (controller area network vehicle interface module) to the DLC3.

  4. Turn the ignition switch to the ON position.

  5. Turn on the tester.

  6. Select the item "DIAGNOSIS / OBD/MOBD / ECT / DATA LIST".

  7. According to the display on tester, read the "DATA LIST".

    Item
    Measurement Item/Range (display)
    Normal Condition
    AT FLUID TEMP
    ATF Temp. Sensor No. 1 Value/min.: -40°C (-40°F) max.: 215°C (419°F)
    1. After Stall Test;
      Approx. 80°C (176°F)
    2. Equal to ambient temperature when cold soak

    HINT:
    When DTC P0712 is output and OBD II scan tool or intelligent tester output is 150°C (302°F) or more, there is a short circuit.
    When DTC P0713 is output and OBD II scan tool or intelligent tester output is -40°C (-40°F), there is an open circuit.
    Measure the resistance between terminal OIL and body ground.


    Temperature Displayed
    Malfunction
    -40°C (-40°F)
    Open circuit
    150 °C (302°F) or more
    Short circuit

    HINT:
    If a circuit related to the ATF temperature sensor becomes open, P0713 is immediately set (in 0.5 second). When P0713 is set, P0711 cannot be detected.
    It is not necessary to inspect the circuit when P0711 is set.

1.INSPECT TRANSMISSION WIRE (ATF TEMPERATURE SENSOR)


    C110342E86
  1. Disconnect the transmission wire connector from the transmission.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Specified Condition
    2 (OT-) - 10 (OT+)
    79 Ω to 156 kΩ
    2 (OT-) - Body ground
    10 kΩ or higher
    10 (OT+) - Body ground
    10 kΩ or higher

    HINT:
    If the resistance is out of the specified range with either the ATF temperature shown in the table below, the driveability of the vehicle may decrease.

    Standard resistance:
    ATF Temperature
    Specified Condition
    20 °C (68°F)
    3 to 4 kΩ
    110°C (230°F)
    0.22 to 0.28 kΩ



NG
REPAIR OR REPLACE TRANSMISSION WIRE
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    G038618E08
  1. Connect the transmission wire connector to the transmission.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Specified Condition
    E5-24 (THO1) - E4-28 (E2)
    79 Ω to 156 kΩ

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check or short):
    Tester Connection
    Specified Condition
    E5-24 (THO1) - Body ground
    10 kΩ or higher
    E4-28 (E2) - Body ground
    ↑



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM