DTC P0710 Transmission Fluid Temperature Sensor "A" Circuit |
DTC P0712 Transmission Fluid Temperature Sensor "A" Circuit Low Input |
DTC P0713 Transmission Fluid Temperature Sensor "A" Circuit High Input |

| DTC No. | DTC Detection Condition | Trouble Area |
| P0710 | (a) and (b) are detected momentarily within 0.5 sec. when neither P0712 nor P0713 is detected (1-trip detection logic) (a) ATF temperature sensor No. 1 resistance is less than 79 Ω. (b) ATF temperature sensor No. 1 resistance is more than 156 kΩ.
|
|
| P0712 | ATF temperature sensor No. 1 resistance is less than 79 Ω for 0.5 sec. or more (1-trip detection logic) |
|
| P0713 | ATF temperature No. 1 sensor resistance is more than 156 kΩ when 15 minutes or more have elapsed after the engine start DTC is detected for 0.5 sec. or more (1-trip detection logic) |
|
| Related DTCs | P0710: ATF temperature sensor/Range check (Chattering) P0712: ATF temperature sensor/Range check (Low resistance) P0713: ATF temperature sensor/Range check (High resistance) |
| Required sensors/Components | ATF temperature sensor (TFT sensor) |
| Frequency of operation | Continuous |
| Duration | 0.5 sec. |
| MIL operation | Immediately |
| Sequence of operation | None |
| The monitor will run whenever this DTC is not present. | None |
| The typical enabling condition is not available. | - |
| The monitor will run whenever this DTC is not present. | None |
| The typical enabling condition is not available. | - |
| The monitor will run whenever this DTC is not present. | None |
| Time after engine start | 15 min. or more |
| TFT (transmission fluid temperature) sensor resistance | Less than 79 Ω or more than 156 kΩ |
| TFT sensor resistance. | Less than 79 Ω |
| TFT sensor resistance. | More than 156 kΩ |
| TFT sensor. | Atmospheric temperature to approx. 130°C (266°F) |

| DATA LIST |
Warm up the engine.
Turn the ignition switch off.
Connect the intelligent tester together with the CAN VIM (controller area network vehicle interface module) to the DLC3.
Turn the ignition switch to the ON position.
Turn on the tester.
Select the item "DIAGNOSIS / OBD/MOBD / ECT / DATA LIST".
According to the display on tester, read the "DATA LIST".
| Item | Measurement Item/Range (display) | Normal Condition |
| AT FLUID TEMP | ATF Temp. Sensor No. 1 Value/min.: -40°C (-40°F) max.: 215°C (419°F) |
|
| Temperature Displayed | Malfunction |
| -40°C (-40°F) | Open circuit |
| 150 °C (302°F) or more | Short circuit |
| 1.INSPECT TRANSMISSION WIRE (ATF TEMPERATURE SENSOR) |
![]() |
Disconnect the transmission wire connector from the transmission.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| 2 (OT-) - 10 (OT+) | 79 Ω to 156 kΩ |
| 2 (OT-) - Body ground | 10 kΩ or higher |
| 10 (OT+) - Body ground | 10 kΩ or higher |
| ATF Temperature | Specified Condition |
| 20 °C (68°F) | 3 to 4 kΩ |
| 110°C (230°F) | 0.22 to 0.28 kΩ |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
![]() |
Connect the transmission wire connector to the transmission.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| E5-24 (THO1) - E4-28 (E2) | 79 Ω to 156 kΩ |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| E5-24 (THO1) - Body ground | 10 kΩ or higher |
| E4-28 (E2) - Body ground | ↑ |
|
| ||||
| OK | ||
| ||