DTC P0976 Shift Solenoid "B" Control Circuit Low (Shift Solenoid Valve S2) |
DTC P0977 Shift Solenoid "B" Control Circuit High (Shift Solenoid Valve S2) |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0976 | ECM detects short in solenoid valve S2 circuit 2 times when solenoid valve S2 is operated (1-trip detection logic) |
|
| P0977 | ECM detects open in solenoid valve S2 circuit 2 times when solenoid valve S2 is not operated (1-trip detection logic) |
|
| Related DTCs | P0976: Shift solenoid valve S2/Range check (Low resistance) P0977: Shift solenoid valve S2/Range check (High resistance) |
| Required sensors/Components | Shift solenoid valve S2 |
| Frequency of operation | Continuous |
| Duration | 0.064 sec. or more |
| MIL operation | Immediately |
| Sequence of operation | None |
| The monitor will run whenever this DTC is not present. | None |
| Shift solenoid valve S2 | ON |
| The monitor will run whenever this DTC is not present. | None |
| Shift solenoid valve S2 | OFF |
| Shift solenoid valve S2 resistance | 8 Ω or less |
| Shift solenoid valve S2 resistance | 100 kΩ or more |
| Shift solenoid valve S2 | Resistance: 11 to 15 Ω at 20°C (68°F) |

| ECM gear shift command | 1st | 2nd | 3rd | 4th | 5th |
| Shift solenoid valve S2 | OFF | ON | ON | OFF | OFF |
| 1.INSPECT TRANSMISSION WIRE (S2) |
![]() |
Disconnect the transmission wire connector from the transmission.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition 20°C (68°F) |
| 15 - Body ground | 11 to 15 Ω |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
![]() |
Connect the transmission connector to the transmission.
Disconnect the connector from the ECM.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition 20°C (68°F) |
| E5-10 (S2) - Body ground | 11 to 15 Ω |
|
| ||||
| OK | ||
| ||
| 3.INSPECT SHIFT SOLENOID VALVE S2 |
![]() |
Remove the shift solenoid valve S2.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition 20°C (68°F) |
| Solenoid Connector (S2) - Solenoid Body (S2) | 11 to 15 Ω |
Connect positive (+) lead to the terminal of solenoid connector, negative (-) lead to the solenoid body.
|
| ||||