Home › TRANSMISSION · A750F AUTOMATIC TRANSMISSION › AUTOMATIC TRANSMISSION SYSTEM (for 2UZ-FE)

DTC    P0976    Shift Solenoid "B" Control Circuit Low (Shift Solenoid Valve S2)

DTC    P0977    Shift Solenoid "B" Control Circuit High (Shift Solenoid Valve S2)

for Preparation Click here


DESCRIPTION

Shifting from 1st to 5th is performed in combination with "ON" and "OFF" operation of the shift solenoid valves SL1, SL2, S1, S2 and SR which is controlled by the ECM. If an open or short circuit occurs in either of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valve to allow the vehicle to be operated smoothly. (In case of an open or short circuit, the ECM stops sending current to the circuit.) Fail safe function (Click here).

DTC No.
DTC Detection Condition
Trouble Area
P0976
ECM detects short in solenoid valve S2 circuit 2 times when solenoid valve S2 is operated (1-trip detection logic)
  1. Short in shift solenoid valve S2 circuit
  2. Shift solenoid valve S2
  3. ECM
P0977
ECM detects open in solenoid valve S2 circuit 2 times when solenoid valve S2 is not operated (1-trip detection logic)
  1. Open in shift solenoid valve S2 circuit
  2. Shift solenoid valve S2
  3. ECM

MONITOR DESCRIPTION

These DTCs indicate an open or short in the shift solenoid valve S2 circuit. When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem and illuminates the MIL and stores the DTC. When the shift solenoid valve S2 is on, if resistance is 8 Ω or less, the ECM determines there is a short in the shift solenoid valve S2 circuit.
When the shift solenoid valve S2 is off, if resistance is 100 kΩ or more, the ECM determines there is an open in the shift solenoid valve S2 circuit (Click here).

MONITOR STRATEGY


Related DTCs
P0976: Shift solenoid valve S2/Range check (Low resistance)
P0977: Shift solenoid valve S2/Range check (High resistance)
Required sensors/Components
Shift solenoid valve S2
Frequency of operation
Continuous
Duration
0.064 sec. or more
MIL operation
Immediately
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


Range check (Low resistance)
P0976: 
The monitor will run whenever this DTC is not present.
None
Shift solenoid valve S2
ON

Range check (High resistance)
P0977: 
The monitor will run whenever this DTC is not present.
None
Shift solenoid valve S2
OFF

TYPICAL MALFUNCTION THRESHOLDS


Range check (Low resistance)
P0976: 
Shift solenoid valve S2 resistance
8 Ω or less

Range check (High resistance)
P0977: 
Shift solenoid valve S2 resistance
100 kΩ or more

COMPONENT OPERATING RANGE


Shift solenoid valve S2
Resistance: 11 to 15 Ω at 20°C (68°F)

WIRING DIAGRAM


C110585E47


INSPECTION PROCEDURE


HINT:
The shift solenoid valve S2 turns ON/OFF normally when the shift lever is in the D position:

ECM gear shift command
1st
2nd
3rd
4th
5th
Shift solenoid valve S2
OFF
ON
ON
OFF
OFF

1.INSPECT TRANSMISSION WIRE (S2)


    C110342E88
  1. Disconnect the transmission wire connector from the transmission.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Specified Condition
    20°C (68°F)
    15 - Body ground
    11 to 15 Ω



NG
Go to step 3
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    G035616E84
  1. Connect the transmission connector to the transmission.

  1. Disconnect the connector from the ECM.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Specified Condition
    20°C (68°F)
    E5-10 (S2) - Body ground
    11 to 15 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM 

3.INSPECT SHIFT SOLENOID VALVE S2


    A110987E04
  1. Remove the shift solenoid valve S2.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Specified Condition
    20°C (68°F)
    Solenoid Connector (S2) - Solenoid Body (S2)
    11 to 15 Ω

  1. Connect positive (+) lead to the terminal of solenoid connector, negative (-) lead to the solenoid body.

    OK:
    The solenoid makes an operating sound.



NG
REPLACE SHIFT SOLENOID VALVE S2