Home › ENGINE ยท 2UZ-FE › COOLING › RADIATOR

RADIATOR > ON-VEHICLE INSPECTION

for Preparation Click here



1. INSPECT RADIATOR CAP SUB-ASSEMBLY

NOTICE:
  1. If the radiator cap is contaminated, rinse it with water.
  2. Before using a radiator cap tester, wet the relief valve and pressure valve with engine coolant or water.
  3. When performing the following steps [A] and [B], keep the tester at an angle of 30° or more above the horizontal.



    Z000570E04
  1. Using a radiator cap tester, slowly pump and check that air comes from the vacuum valve [A].

    Pumping speed:
    1 push every 3 seconds or more

    NOTICE:
    Push the pump at a constant speed.

    If air does not come from the vacuum valve, replace the reservoir cap.

  1. Pump the tester, then measure the relief valve opening pressure [B].

    Pumping speed:
    1 push every second

    NOTICE:
    The above pumping speed is for the first pumping only (in order to close the vacuum valve). After the first pumping, the pumping speed can be reduced.

    HINT:
    Use the tester's maximum reading as the opening pressure.

    Standard opening pressure:
    93 to 123 kPa (0.95 to 1.25 kgf*cm2, 13.5 to 17.8 psi)

    Minimum opening pressure:
    78 kPa (0.8 kgf*cm2, 11.4 psi)

    If the opening pressure is less than the minimum, replace the radiator cap.