DTC P0100 Mass Air Flow Circuit Malfunction |
DTC P0102 Mass Air Flow Circuit Low |
DTC P0103 Mass Air Flow Circuit High |

| DTC No. | DTC Detection Condition | Trouble Area |
| P0100 | Open or short in mass air flow meter circuit with more than 3 seconds engine speed 4,000 rpm or less |
|
| P0102 | Open or short in mass air flow meter circuit with more than 3 seconds engine speed 4,000 rpm or less |
|
| P0103 | Open in mass air flow meter circuit with more than 3 seconds (E2G circuit) engine speed 4,000 rpm or less Short in mass air flow meter circuit with more than 3 seconds (+B circuit) engine speed 4,000 rpm or less |
|
| Mass Air Flow Rate (g/sec) | Malfunction |
| Approximately 0.0 |
|
| 271.0 or more | E2G circuit open |
| Related DTCs | P0100: MAF meter range check (fluttering) P0102: MAF meter range check (low voltage) P0103: MAF meter range check (high voltage) |
| Required Sensors/Components (Main) | MAF meter |
| Required Sensors/Components (Related) | Crankshaft position sensor |
| Frequency of operation | Continuous |
| Duration | 3 seconds |
| MIL operation | Immediate: Engine RPM is less than 4,000 rpm 2 driving cycles: Engine RPM is 4,000 rpm or more |
| Sequence of operation | None |
| Monitor runs whenever following DTCs not present | None |
| The typical enabling condition is not available | - |
| MAF meter voltage | Less than 0.2 V or more than 4.9 V |
| MAF meter voltage | Less than 0.2 V |
| MAF meter voltage | More than 4.9 V |
| MAF meter voltage | Between 0.4 and 2.2 V |

| 1.READ VALUE OF INTELLIGENT TESTER (MASS AIR FLOW RATE) |
Connect the intelligent tester to the CAN VIM. Then connect the CAN VIM to the DLC3.
Allow the engine to idle.
Enter the following menus: DIAGNOSIS / ENHANCED OBD II / DATA LIST / ALL / MAF.
Read the values displayed on the tester.
| Mass Air Flow Rate (g/sec) | Proceed to |
| 0.0 | A |
| 271.0 or more | B |
| Between 1.0 and 270.0 (*1) | C |
|
| ||||
|
| ||||
| A | |
| 2.INSPECT MASS AIR FOW METER (POWER SOURCE VOLTAGE) |
![]() |
Disconnect the M1 Mass Air Flow (MAF) meter connector.
Turn the ignition switch ON.
Measure the voltage of the wire harness side connector.
| Tester Connection | Specified Condition |
| +B (M1-1) - Body ground | 9 to 14 V |
Reconnect the MAF meter connector.
|
| ||||
| OK | |
| 3.INSPECT ECM (VG VOLTAGE) |
![]() |
Start the engine.
Measure the voltage of the E4 ECM connector.
| Tester Connection | Condition | Specified Condition |
| VG (E4-30) - E2G (E4-29) | Engine is idling | 0.5 to 3.0 V |
|
| ||||
| NG | |
| 4.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM) |
![]() |
Disconnect the M1 mass air flow meter connector.
Disconnect the E4 ECM connector.
Measure the resistance between the wire harness side connectors.
| Tester Connection | Specified Condition |
| VG (M1-3) - VG (E4-30) | Below 1 Ω |
| E2G (M1-2) - E2G (E4-29) | Below 1 Ω |
| VG (M1-3) or VG (E4-30) - Body ground | 10 kΩ or higher |
Reconnect the ECM connector.
Reconnect the MAF connector.
|
| ||||
| OK | ||
| ||
| 5.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - EFI RELAY) |
![]() |
Remove the EFI No. 2 fuse from the engine room R/B.
Measure the resistance in the EFI No. 2 fuse.
Reinstall the EFI No. 2 fuse.
Disconnect the M1 mass air flow meter connector.
Remove the EFI relay from the engine room R/B.
Measure the resistance between the wire harness side connectors.
| Tester Connection | Specified Condition |
| +B (M1-1) - Engine room R/B (EFI relay terminal 3) | Below 1 Ω |
| +B (M1-1) or Engine room R/B (EFI relay terminal 3) - Body ground | 10 kΩ or higher |
Reconnect the MAF meter connector.
Reinstall the EFI relay.
|
| ||||
| OK | ||
| ||
| 6.INSPECT ECM (SENSOR GROUND) |
![]() |
Measure the resistance of the ECM connector.
| Tester Connection | Specified Condition |
| E2G (E4-29) - Body ground | Below 1 Ω |
|
| ||||
| OK | |
| 7.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM) |
![]() |
Disconnect the M1 mass air flow meter connector.
Disconnect the E4 ECM connector.
Measure the resistance between the wire harness side connectors.
| Tester Connection | Specified Condition |
| VG (M1-3) - VG (E4-30) | Below 1 Ω |
| E2G (M1-2) - E2G (E4-29) | Below 1 Ω |
| VG (M1-3) or VG (E4-30) - Body ground | 10 kΩ or higher |
| E2G (M1-2) or E2G (E4-29) - Body ground | 10 kΩ or higher |
Reconnect the MAF meter connector.
Reconnect the ECM connector.
|
| ||||
| OK | ||
| ||