Home › RESTRAINTS › SUPPLEMENTAL RESTRAINT SYSTEM › OCCUPANT CLASSIFICATION SYSTEM

OCCUPANT CLASSIFICATION SYSTEM > TERMINALS OF ECU

for Preparation Click here



OCCUPANT CLASSIFICATION ECU

C110373E04


Symbols (Terminal No.)
Wiring Color
Terminal Description
Condition
Specification
+B (O3-1) - GND (O6-3)
R - W-B
Power source (ECU-B Fuse)
Always
10 to 14 V
DIA (O3-2) - GND (O6-3)
V - W-B
Diagnosis (DLC3)
IG switch ON
Pulse generation
GND (O3-3) - Body ground
W-B - Body ground
Ground
Always
Below 1 Ω
FSR- (O3-4) - GND (O3-3)
B - W-B
Center airbag sensor assembly communication line (-)
Always
Below 1 Ω
BGND (O3-5) - GND (O3-3)
GR - W-B
Passenger side buckle switch ground line
Always
Below 1 Ω
IG (O3-7) - GND (O3-3)
BR - W-B
Power source (IG2 Fuse)
IG switch ON
10 to 14 V
FSR+ (O3-8) - FSR- (O3-4)
W - B
Center airbag sensor assembly communication line
IG switch ON
Pulse generation
BSW (O3-9) - BGND (O3-5)
L - GR
Passenger side buckle switch line
Buckle switch ON
Buckle switch OFF
Pulse generation
SGD1 (O4-1) - GND (O3-3)
G - W-B
Occupant classification sensor front LH ground line
Always
Below 1 Ω
SGD2 (O4-2) - GND (O3-3)
O - W-B
Occupant classification sensor front RH ground line
Always
Below 1 Ω
SGD3 (O4-3) - GND (O3-3)
W - W-B
Occupant classification sensor rear LH ground line
Always
Below 1 Ω
SGD4 (O4-4) - GND (O3-3)
BR - W-B
Occupant classification sensor rear RH ground line
Always
Below 1 Ω
SVC3 (O4-5) - SGD3 (O4-3)
GR - W
Occupant classification sensor rear LH power supply line
IG switch ON, a load is applied to occupant classification sensor rear LH
4.5 to 5.1 V
SVC4 (O4-6) - SGD4 (O4-4)
V - BR
Occupant classification sensor rear RH power supply line
IG switch ON, a load is applied to occupant classification sensor rear RH
4.5 to 5.1 V
SIG1 (O4-7) - SGD1 (O4-1)
BR - G
Occupant classification sensor front LH signal line
IG switch ON, a load is applied to occupant classification sensor front LH
0.2 to 4.7 V
SIG2 (O4-8) - SGD2 (O4-2)
L - O
Occupant classification sensor front RH signal line
IG switch ON, a load is applied to occupant classification sensor front RH
0.2 to 4.7 V
SIG3 (O4-9) - SGD3 (O4-3)
Y - W
Occupant classification sensor rear LH signal line
IG switch ON, a load is applied to occupant classification sensor rear LH
0.2 to 4.7 V
SIG4 (O4-10) - SGD4 (O4-4)
B - BR
Occupant classification sensor rear RH signal line
IG switch ON, a load is applied to occupant classification sensor rear RH
0.2 to 4.7 V
SVC1 (O4-11) - SGD1 (O4-1)
R - G
Occupant classification sensor front LH power supply line
IG switch ON, a load is applied to occupant classification sensor front LH
4.5 to 5.1 V
SVC2 (O4-12) - SGD2 (O4-2)
W - O
Occupant classification sensor front RH power supply line
IG switch ON, a load is applied to occupant classification sensor front RH
4.5 to 5.1 V