FUEL PUMP RELAY > INSPECTION |
| 1. INSPECT FUEL PUMP RELAY ASSEMBLY |
![]() |
Check the resistance.
Using an ohmmeter, measure the resistance between the terminals.
| Tester Connection | Specified Condition |
| 3 - 4 | Below 1 Ω |
| 3 - 5 | 10 kΩ or higher |
| 3 - 4 | 10 kΩ or higher (Apply battery voltage to terminals 1 and 2) |
| 3 - 5 | Below 1 Ω (Apply battery voltage to terminals 1 and 2) |