Home › BODY › WINDSHIELD / WINDOWGLASS › POWER WINDOW CONTROL SYSTEM

POWER WINDOW CONTROL SYSTEM > Power Windows do not Operate at All

for Preparation Click here


DESCRIPTION

If all the door glasses do not operate or if the operation function after the ignition switch is turned OFF does not operate, no power may be supplied to the power window master switch or the power window master switch itself may malfunction.

WIRING DIAGRAM


B140740E01


INSPECTION PROCEDURE

1.INSPECT FUSE (POWER)
  1. Remove the fuse from the instrument panel J/B assembly.

  1. Check the continuity.

    Standard:
    Continuity



NG
REPLACE FUSE
OK


2.INSPECT INSTRUMENT PANEL J/B ASSEMBLY


    B063172E01
  1. Remove the power window relay.

  1. Turn the ignition switch ON.

  1. Check the voltage between the J/B terminals 1 and 2.

Standard:
10 to 14 V



NG
REPLACE INSTRUMENT PANEL J/B ASSEMBLY
OK


3.INSPECT POWER WINDOW RELAY (POWER)


    B060778E82
  1. Remove the relay from the backside of the instrument panel J/B assembly.

  1. Check the continuity.

  1. Check the voltage between the J/B terminals 1 and 2.

    Standard:
    Terminal No.
    Condition
    Specified Condition
    1 - 2
    Constant
    Continuity
    3 - 5
    Apply battery voltage to terminal 1 and 2
    Continuity



NG
REPLACE POWER WINDOW RELAY
OK


4.CHECK WIRE HARNESS (TERMINAL B2, BW OR E)


    B062895E13
  1. Disconnect the D17 switch connector.

  1. Check the voltage or continuity between each terminal of the wire harness side connector and the body ground.

    Standard:
    Symbols (Terminal No.)
    Condition
    Specified Condition
    B2 (D17-11) - Body ground
    Ignition ON
    10 to 14 V
    BW (D17-7) - Body ground
    Constant
    10 to 14 V
    E (D17-1) - Body ground
    Constant
    Continuity



NG
REPAIR OR REPLACE HARNESS AND CONNECTOR
OK


5.CHECK WIRE HARNESS (TERMINAL B)


    B062895E13
  1. Turn the ignition switch ON.

  1. Check the voltage between terminal 6 of the wire harness side connector and the body ground.

    Standard:
    Terminal No.
    Condition
    Specified Condition
    B (D17-6) - Body ground
    Ignition switch ON
    10 to 14 V



OK
REPLACE POWER WINDOW MASTER SWITCH ASSEMBLY
NG

REPAIR OR REPLACE HARNESS AND CONNECTOR (POWER WINDOW RELAY - MASTER SWITCH)