POWER WINDOW CONTROL SYSTEM > Power Windows do not Operate at All |

| 1.INSPECT FUSE (POWER) |
Remove the fuse from the instrument panel J/B assembly.
Check the continuity.
|
| ||||
| OK | |
| 2.INSPECT INSTRUMENT PANEL J/B ASSEMBLY |
![]() |
Remove the power window relay.
Turn the ignition switch ON.
Check the voltage between the J/B terminals 1 and 2.
|
| ||||
| OK | |
| 3.INSPECT POWER WINDOW RELAY (POWER) |
![]() |
Remove the relay from the backside of the instrument panel J/B assembly.
Check the continuity.
Check the voltage between the J/B terminals 1 and 2.
| Terminal No. | Condition | Specified Condition |
| 1 - 2 | Constant | Continuity |
| 3 - 5 | Apply battery voltage to terminal 1 and 2 | Continuity |
|
| ||||
| OK | |
| 4.CHECK WIRE HARNESS (TERMINAL B2, BW OR E) |
![]() |
Disconnect the D17 switch connector.
Check the voltage or continuity between each terminal of the wire harness side connector and the body ground.
| Symbols (Terminal No.) | Condition | Specified Condition |
| B2 (D17-11) - Body ground | Ignition ON | 10 to 14 V |
| BW (D17-7) - Body ground | Constant | 10 to 14 V |
| E (D17-1) - Body ground | Constant | Continuity |
|
| ||||
| OK | |
| 5.CHECK WIRE HARNESS (TERMINAL B) |
![]() |
Turn the ignition switch ON.
Check the voltage between terminal 6 of the wire harness side connector and the body ground.
| Terminal No. | Condition | Specified Condition |
| B (D17-6) - Body ground | Ignition switch ON | 10 to 14 V |
|
| ||||
| NG | ||
| ||