SFI SYSTEM > CHECKING MONITOR STATUS |
| Outline |
The monitor results and test values can be checked with the OBD II scan tool or the intelligent tester.
The engine control module (ECM) monitors the emissions-related components such as the thermostat, catalyst converter and evaporative emissions (EVAP), and determines whether they are functioning normally or not. When finished monitoring, the ECM stores the monitor results and the test values.
The monitor result indicates whether the component is functioning normally or not. The test value is the value that was used to determine the monitor result. If the test value is outside the test limit (malfunction criterion), the ECM determines the component is malfunctioning. Some emissions-related components have multiple test values to determine monitor result. If one of these test values is outside test limit, the ECM determines the component is malfunctioning.
| Description |
The test value and test limit information are described as shown in the following table. This information is included under "MONITOR RESULT" in the emissions-related DTC sections:
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
| $E1 | $E8 | Multiply by 0.1 [°C] | ECT sensor output when estimated ECT reached to malfunction criteria | Malfunction criteria | Maximum test limit |
| Procedure (using intelligent tester) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG).
Turn the tester or scan tool ON.
Clear DTCs.
Allow the vehicle to drive in accordance with the applicable drive pattern described in the READINESS MONITOR DRIVE PATTERN (Click here).
Check the monitor result. Select the intelligent tester menus: DIAGNOSIS, ENHANCED OBD II, MONITOR INFO and MONITOR STATUS. The monitor result appears after the component name.
Check the test value(s). Select the intelligent tester menus: DIAGNOSIS, ENHANCED OBD II, MONITOR INFO and TEST RESULT.
Select the component and press ENTER. If the monitor result has been COMPL or INCMPL, the accuracy test value appears.
Compare the test value with the test limits, MIN and MAX.