DTC P0351 Ignition Coil "A" Primary / Secondary Circuit |
DTC P0352 Ignition Coil "B" Primary / Secondary Circuit |
DTC P0353 Ignition Coil "C" Primary / Secondary Circuit |
DTC P0354 Ignition Coil "D" Primary / Secondary Circuit |
DTC P0355 Ignition Coil "E" Primary / Secondary Circuit |
DTC P0356 Ignition Coil "F" Primary / Secondary Circuit |

| DTC No. | DTC Detection Conditions | Trouble Areas |
| P0351 P0352 P0353 P0354 P0355 P0356 | No IGF signal to ECM while engine running (1 trip detection logic) |
|

| Items | Contents |
| Terminals | CH1: IGT1, IGT2, IGT3, IGT4, IGT5, IGT6 - E1 CH2: IGF1 - E1 |
| Equipment Settings | 2 V/Division, 20 ms/Division |
| Conditions | Cranking or idling |

| Related DTCs | P0351: No.1 ignition coil with igniter circuit malfunction P0352: No.2 ignition coil with igniter circuit malfunction P0353: No.3 ignition coil with igniter circuit malfunction P0354: No.4 ignition coil with igniter circuit malfunction P0355: No.5 ignition coil with igniter circuit malfunction P0356: No.6 ignition coil with igniter circuit malfunction |
| Required Sensors / Components (Main) | Igniter |
| Required Sensors / Components (Related) | Crankshaft position sensor |
| Frequency of Operation | Continuous |
| Duration | 0.256 seconds +4 sparks |
| MIL Operation | Immediate |
| Sequence of Operation | None |
| The monitor will run whenever these DTCs are not present | None |
| Engine speed | 1,500 rpm or less |
| Either of the following conditions is met: | Condition 1 or 2 |
| 1. Following conditions are met: | Condition (a) and (b) |
| (a) Engine RPM | 500 rpm or less |
| (b) Battery voltage | 6 V or more |
| 2. Following conditions are met: | Condition (c), (d) and (e) |
| (c) Engine RPM | More than 500 rpm |
| (d) Battery voltage | 10 V or more |
| (e) Number of sparks after CPU is reset | 5 sparks or more |
| Ignition signal fail count | More than 2 |
| Ignition signal fail count is on the right: | When IGF does not return despite sending IGT. |
| IGF signal | Igniter outputs IGF signal when it receives IGT signal from ECM |

| 1.CHECK WHETHER DTC OUTPUT RECURS (DTC P0351, P0352, P0353, P0354, P0355 OR P0356) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the tester ON.
Clear DTCs (Click here).
Shuffle arrangement of the ignition coils with igniters (among No. 1 to No. 6 cylinders).
Perform a simulation test.
Check DTCs displayed on the tester.
| Display (DTC Output) | Proceed to |
| P0351, P0352, P0353, P0354, P0355 or P0356 | A |
| Any other DTCs | B |
|
| ||||
| A | |
| 2.INSPECT ECM (IGT1, IGT2, IGT3, IGT4, IGT5 IGT6 AND IGF1 SIGNAL) |
![]() |
Inspect the ECM using an oscilloscope.
While cranking or idling, check the waveform between the terminals of the E4 and E6 ECM connector.
| Tester Connections | Specified Conditions |
| IGT1 (E4-8) - E1 (E6-1) | Correct waveform shown |
| IGT2 (E4-9) - E1 (E6-1) | Correct waveform shown |
| IGT3 (E4-10) - E1 (E6-1) | Correct waveform shown |
| IGT4 (E4-11) - E1 (E6-1) | Correct waveform shown |
| IGT5 (E4-12) - E1 (E6-1) | Correct waveform shown |
| IGT6 (E4-13) - E1 (E6-1) | Correct waveform shown |
| IGF1 (E4-24) - E1 (E6-1) | Correct waveform shown |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (IGNITION COIL ASSEMBLY - ECM) |
![]() |
Disconnect the I1, I2, I3, I4, I5 or I6 ignition coil with igniter connector.
Disconnect the E4 ECM connector.
Measure the resistance.
| Tester Connections | Specified Conditions |
| IGF (I1-2) - IGF1 (E4-24) | Below 1 Ω |
| IGF (I2-2) - IGF1 (E4-24) | Below 1 Ω |
| IGF (I3-2) - IGF1 (E4-24) | Below 1 Ω |
| IGF (I4-2) - IGF1 (E4-24) | Below 1 Ω |
| IGF (I5-2) - IGF1 (E4-24) | Below 1 Ω |
| IGF (I6-2) - IGF1 (E4-24) | Below 1 Ω |
| Tester Connections | Specified Conditions |
| IGT (I1-3) - IGT1 (E4-8) | Below 1 Ω |
| IGT (I2-3) - IGT2 (E4-9) | Below 1 Ω |
| IGT (I3-3) - IGT3 (E4-10) | Below 1 Ω |
| IGT (I4-3) - IGT4 (E4-11) | Below 1 Ω |
| IGT (I5-3) - IGT5 (E4-12) | Below 1 Ω |
| IGT (I6-3) - IGT6 (E4-13) | Below 1 Ω |
| Tester Connections | Specified Conditions |
| IGF (I1-2) or IGF1 (E4-24) - Body ground | 10 kΩ or higher |
| IGF (I2-2) or IGF1 (E4-24) - Body ground | 10 kΩ or higher |
| IGF (I3-2) or IGF1 (E4-24) - Body ground | 10 kΩ or higher |
| IGF (I4-2) or IGF1 (E4-24) - Body ground | 10 kΩ or higher |
| IGF (I5-2) or IGF1 (E4-24) - Body ground | 10 kΩ or higher |
| IGF (I6-2) or IGF1 (E4-24) - Body ground | 10 kΩ or higher |
| Tester Connections | Specified Conditions |
| IGT (I1-3) or IGT1 (E4-8) - Body ground | 10 kΩ or higher |
| IGT (I2-3) or IGT2 (E4-9) - Body ground | 10 kΩ or higher |
| IGT (I3-3) or IGT3 (E4-10) - Body ground | 10 kΩ or higher |
| IGT (I4-3) or IGT4 (E4-11) - Body ground | 10 kΩ or higher |
| IGT (I5-3) or IGT5 (E4-12) - Body ground | 10 kΩ or higher |
| IGT (I6-3) or IGT6 (E4-13) - Body ground | 10 kΩ or higher |
Reconnect the ECM connector.
Reconnect the ignition coil with igniter connector.
|
| ||||
| OK | |
| 4.INSPECT IGNITION COIL ASSEMBLY (POWER SOURCE) |
![]() |
Disconnect the I1, I2, I3, I4, I5 or I6 ignition coil with igniter connector.
Measure the resistance.
| Tester Connections | Specified Conditions |
| GND (I1-4) - Body ground | Below 1 Ω |
| GND (I2-4) - Body ground | Below 1 Ω |
| GND (I3-4) - Body ground | Below 1 Ω |
| GND (I4-4) - Body ground | Below 1 Ω |
| GND (I5-4) - Body ground | Below 1 Ω |
| GND (I6-4) - Body ground | Below 1 Ω |
Turn the ignition switch on.
Measure the voltage between the terminals of the wire harness side connector.
| Tester Connections | Specified Conditions |
| +B (I1-1) - GND (I1-4) | 9 to 14 V |
| +B (I2-1) - GND (I2-4) | 9 to 14 V |
| +B (I3-1) - GND (I3-4) | 9 to 14 V |
| +B (I4-1) - GND (I4-4) | 9 to 14 V |
| +B (I5-1) - GND (I5-4) | 9 to 14 V |
| +B (I6-1) - GND (I6-4) | 9 to 14 V |
Reconnect the ignition coil with igniter connector.
|
| ||||
| OK | ||
| ||
| 5.CHECK HARNESS AND CONNECTOR (IGNITION COIL ASSEMBLY - IGNITION SWITCH) |
![]() |
Disconnect the I1, I2, I3, I4, I5 or I6 ignition coil with igniter connector.
Disconnect the I18 ignition switch connector.
Measure the resistance.
| Tester Connections | Specified Conditions |
| +B (I1-1) - IG2 (I18-6) | Below 1 Ω |
| +B (I2-1) - IG2 (I18-6) | Below 1 Ω |
| +B (I3-1) - IG2 (I18-6) | Below 1 Ω |
| +B (I4-1) - IG2 (I18-6) | Below 1 Ω |
| +B (I5-1) - IG2 (I18-6) | Below 1 Ω |
| +B (I6-1) - IG2 (I18-6) | Below 1 Ω |
| Tester Connections | Specified Conditions |
| +B (I1-1) or IG2 (I18-6) - Body ground | 10 kΩ or higher |
| +B (I2-1) or IG2 (I18-6) - Body ground | 10 kΩ or higher |
| +B (I3-1) or IG2 (I18-6) - Body ground | 10 kΩ or higher |
| +B (I4-1) or IG2 (I18-6) - Body ground | 10 kΩ or higher |
| +B (I5-1) or IG2 (I18-6) - Body ground | 10 kΩ or higher |
| +B (I6-1) or IG2 (I18-6) - Body ground | 10 kΩ or higher |
Reconnect the ignition coil with igniter connector.
Reconnect the ignition switch connector.
|
| ||||
| OK | ||
| ||