DTC P0110 Intake Air Temperature Circuit |
DTC P0112 Intake Air Temperature Circuit Low Input |
DTC P0113 Intake Air Temperature Circuit High Input |

| DTC No. | Proceed to | DTC Detection Conditions | Trouble Area |
| P0110 | Step 1 | Open or short in Intake Air Temperature (IAT) sensor circuit for 0.5 seconds (1 trip detection logic) |
|
| P0112 | Step 4 | Short in Intake Air Temperature (IAT) sensor circuit for 0.5 seconds (1 trip detection logic) |
|
| P0113 | Step 2 | Open in Intake Air Temperature (IAT) sensor circuit for 0.5 seconds (1 trip detection logic) |
|
| Temperature Displayed | Malfunctions |
| -40°C (-40°F) | Open circuit |
| 140°C (284°F) or higher | Short circuit |
| Related DTCs | P0110: IAT sensor range check (Fluttering) P0112: IAT sensor range check (Low voltage) P0113: IAT sensor range check (High voltage) |
| Required Sensors / Components (Main) | Intake Air Temperature (IAT) sensor |
| Required sensors / Components (Related) | - |
| Frequency of Operation | Continuous |
| Duration | 0.5 seconds |
| MIL Operation | Immediate |
| Sequence of Operation | None |
| The monitor will run whenever these DTCs are not present | None |
| Intake air temperature sensor voltage | Less than 0.18 V or more than 4.91 V [More than 140°C (284°F), or less than -40°C (-40°F)] |
| Intake air temperature sensor voltage | Less than 0.18 V [More than 140°C (284°F)] |
| Intake air temperature sensor voltage | More than 4.91 V [Less than -40°C (-40°F)] |
| Intake air temperature sensor voltage | 0.18 V to 4.91 V [-40 to 140°C (-40 to 284°F)] |

| 1.READ VALUE OF INTELLIGENT TESTER (INTAKE AIR TEMPERATURE) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on.
Turn the tester on.
Select the following menu items: DIAGNOSIS / ENHANCEDOBD II / DATA LIST / PRIMARY / INTAKE AIR.
Read the value displayed on the tester.
| Temperature Displayed | Proceed to |
| -40°C (-40°F) | A |
| 140°C (284°F) or higher | B |
| Same as actual IAT | C |
|
| ||||
|
| ||||
| A | |
| 2.READ VALUE OF INTELLIGENT TESTER (CHECK FOR OPEN IN WIRE HARNESS) |
![]() |
Disconnect the M1 Mass Air Flow (MAF) meter connector.
Connect terminals THA and E2 of the MAF meter wire harness side connector.
Connect the intelligent tester to the DLC3.
Turn the ignition switch on.
Turn the tester on.
Select the following menu items: DIAGNOSIS / ENHANCED OBD II / DATA LIST / PRIMARY / INTAKE AIR.
Read the value displayed on the tester.
Reconnect the MAF meter connector.
|
| ||||
| NG | |
| 3.READ VALUE OF INTELLIGENT TESTER (CHECK FOR OPEN IN ECM) |
![]() |
Disconnect the M1 MAF meter connector.
Connect terminals THA and E2 of the B45 ECM connector.
Connect the intelligent tester to the DLC3.
Turn the ignition switch on.
Turn the tester on.
Select the following menu items: DIAGNOSIS / ENHANCED OBD II / DATA LIST / PRIMARY / INTAKE AIR.
Read the value displayed on the tester.
Reconnect the MAF meter connector.
|
| ||||
| NG | ||
| ||
| 4.READ VALUE OF INTELLIGENT TESTER (CHECK FOR SHORT IN WIRE HARNESS) |
![]() |
Disconnect the M1 MAF meter connector.
Connect the intelligent tester to the DLC3.
Turn the ignition switch on.
Turn the tester on.
Select the following menu items: DIAGNOSIS / ENHANCED OBD II / DATA LIST / PRIMARY / INTAKE AIR.
Read the value displayed on the tester.
Reconnect the MAF meter connector.
|
| ||||
| NG | |
| 5.READ VALUE OF INTELLIGENT TESTER (CHECK FOR SHORT IN ECM) |
![]() |
Disconnect the E4 ECM connector.
Connect the intelligent tester to the DLC3.
Turn the ignition switch on.
Turn the tester on.
Select the following menu items: DIAGNOSIS / ENHANCED OBD II / DATA LIST / PRIMARY / INTAKE AIR.
Read the value displayed on the tester.
Reconnect the ECM connector.
|
| ||||
| NG | ||
| ||