SFI SYSTEM > Cranking Holding Function Circuit |

| 1.CHECK OPERATION OF ENGINE CRANKING |
When turning the ignition switch to the ST position, check whether the starter motor starts.
|
| ||||
| NG | |
| 2.READ VALUE OF INTELLIGENT TESTER (STA SIGNAL) |
Connect the intelligent tester to the DLC3.
Select the following menu items: DIAGNOSIS / ENHANCED OBD II / DATA LIST / ALL / STARTER SIG.
Read the values.
| STARTER SIG | Ignition Switch Position |
| OFF | ON |
| ON | START |
|
| ||||
| NG | |
| 3.INSPECT ECM (STAR AND STSW VOLTAGE) |
![]() |
Measure the voltage between the terminals of the E5 and E6 ECM connectors, while cranking the engine.
| Tester Connection | Specified Condition |
| STAR/NSW (E5-8) - E1 (E6-1) | 9 to 14 V |
| STSW (E5-12) - E1 (E6-1) | 9 to 14 V |
| Terminal STAR | Terminal STSW | Proceed to |
| 9 to 14 V | 9 to 14 V | A |
| 0 V | 9 to 14 V | B |
| 0 V | 0 V | C |
|
| ||||
|
| ||||
| A | |
| 4.INSPECT PARK/NEUTRAL POSITION SWITCH ASSEMBLY |
![]() |
Disconnect the P1 park/neutral position switch connector.
Check for continuity between each terminal shown below when the shift lever is moved to each position.
| Shift Position | Tester Connection | Specified Condition |
| P | 1 - 3 6 - 9 | Continuity |
| R | 2 - 3 | |
| N | 3 - 5 6 - 9 | |
| D | 3 - 7 | |
| 3 | 3 - 4 | |
| 2, L | 3 - 8 |
|
| ||||
| OK | ||
| ||
| 5.INSPECT STARTER RELAY |
![]() |
Remove the starter relay from the engine room R/B.
Inspect the starter relay.
| Tester Connection | Specified Condition |
| 1 - 2 | Continuity |
| 3 - 5 | No continuity |
| Continuity (Apply battery voltage to terminals 1 and 2) |
Reinstall the starter relay.
|
| ||||
| OK | |
| 6.CHECK HARNESS AND CONNECTOR (PARK/NEUTRAL POSITION SWITCH - BODY GROUND) |
![]() |
Check the harness and connector between the park/neutral position switch and starter relay.
Disconnect the P1 park/neutral position switch connector.
Remove the starter relay from the engine room R/B.
Measure the resistance between the wire harness side connectors.
| Tester Connections | Specified Conditions |
| Park/neutral position switch (P1-6) - Starter relay (1) | Below 1 Ω |
| Tester Connections | Specified Conditions |
| Park/neutral position switch (P1-6) or Starter relay (1) - Body ground | 10 kΩ or higher |
Reconnect the park/neutral position switch connector.
Reinstall the starter relay.
Check the harness and connector between the starter relay, and body ground.
Measure the resistance between each relay and body ground.
| Tester Connections | Specified Conditions |
| Starter relay (2) - Body ground | Below 1 Ω |
Reinstall the starter relay.
|
| ||||
| OK | |
| 7.INSPECT ENGINE ROOM RELAY BLOCK (STARTER RELAY VOLTAGE) |
![]() |
Remove the starter relay from the engine room R/B.
Measure the voltage between the terminal of the engine room R/B and body ground.
| Tester Connections | Specified Conditions |
| Starter relay (5) - Body ground | 9 to 14 V |
Reinstall the starter relay.
|
| ||||
| OK | |
| 8.INSPECT STARTER ASSEMBLY |
Inspect the starter assembly (Click here for Standard, Click here for Cold area).
|
| ||||
| OK | ||
| ||
| 9.CHECK FUSE (STA NO. 2) |
![]() |
Remove the STA No. 2 fuse from the driver side J/B.
Check for continuity in the STA No. 2 fuse.
Reinstall the STA No. 2 fuse.
|
| ||||
| OK | |
| 10.INSPECT IGNITION OR STARTER SWITCH ASSEMBLY |
![]() |
Disconnect the I18 ignition switch connector.
Check for continuity between the terminals shown in the chart below.
| Switch Position | Tester Connection | Specified Condition |
| LOCK | All terminal to terminal | No continuity |
| ACC | 2 - 3 | Continuity |
| ON | 2 - 3, 2 - 4, 3 - 4, 6 - 7 | Continuity |
| START | 1 - 2, 1 - 4, 2 - 4, 6 - 7, 6 - 8, 7 - 8 | Continuity |
Reconnect the ignition switch connector.
|
| ||||
| OK | ||
| ||