Home › BODY ELECTRICAL › LIGHTING › HAZARD WARNING SWITCH

HAZARD WARNING SWITCH > INSPECTION

for Preparation Click here



1. INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY


    E065753
  1. Check that there is continuity between terminals at each switch position as shown in the chart.
    Switch operation
    Tester connection
    Specified condition
    OFF
    2 - 3
    No continuity
    ON
    2 - 3
    Continuity
    Illumination circuit
    4 - 5
    Continuity

  1. Inspect illumination operation.

    1. Connect the battery positive (+) lead to terminal 4 and the battery negative (-) lead to terminal 5, then check that the illumination lights up.