Home › STEERING › POWER STEERING › VANE PUMP

VANE PUMP > INSPECTION

for Preparation Click here



1. INSPECT OIL CLEARANCE


    F001809E02
  1. Using a micrometer and a caliper gauge, measure the oil clearance.

    Standard clearance:
    0.03 to 0.05 mm (0.0012 to 0.0020 in.)
    Maximum clearance:
    0.07 mm (0.0028 in.)

    If it is more than the maximum, replace the shaft and vane pump front housing.



2. INSPECT VANE PUMP ROTOR AND VANE PUMP PLATES CLEARANCE


    N000372E07
  1. Using a micrometer, measure the height, thickness and length of the 10 vane plates.

    Minimum height:
    8.6 mm (0.33858 in.)
    Minimum thickness:
    1.397 mm (0.05500 in.)
    Minimum length:
    14.991 mm (0.59020 in.)



    R010282E01
    R013897E01
  1. Using a feeler gauge, measure the clearance between the vane pump rotor grove and vane plate.

    Maximum clearance:
    0.033 mm (0.00130 in.)

    If it is more than the maximum, replace the plate and/or rotor with one having the same mark stamped on the cam ring.

    Inscribed mark:
    1, 2, 3, 4, or None

    HINT:
    There are 5 vane plate lengths with the following rotor and cam ring marks:
    Rotor and cam ring mark
    Vane plate part number
    Vane plate length
    mm (in.)
    None
    44345-26010
    14.999 - 15.001
    (0.59051 - 0.59059)
    1
    44345-26020
    14.997 - 14.999
    (0.59043 - 0.59051)
    2
    44345-26030
    14.995 - 14.997
    (0.59035 - 0.59043)
    3
    44345-26040
    14.993 - 14.995
    (0.59027 - 0.59035)
    4
    44345-26050
    14.991 - 14.993
    (0.59020 - 0.59027)



3. INSPECT FLOW CONTROL VALVE


    W004759
  1. Coat the flow control valve with power steering fluid and check that it falls smoothly into the flow control valve hole by its own weight.



    F004865E01
    F004866E01
  1. Check the flow control valve for leakage. Close one of the holes and apply compressed air of 392 to 490 kPa (4 to 5 kgf*cm2, 57 to 71 psi) into the opposite side hole, and confirm that air does not come out from the end holes.
    If necessary, replace the valve with one having the same letter as inscribed on the front housing.

    Inscribed mark:
    A, B, C, D, E or F



4. INSPECT FLOW CONTROL VALVE COMPRESSION SPRING


    R008702E02
  1. Using vernier calipers, measure the free length of the spring.

    Minimum free length:
    33.2 mm (1.307 in.)

    If it is not within the specification, replace the spring.



5. INSPECT PRESSURE PORT UNION
If the pressure union seat in the pressure port union is remarkably damaged and it may cause fluid leakage, replace the pressure port union.