Home
›
ENGINE · 1GR-FE
›
ENGINE CONTROL SYSTEM
›
KNOCK SENSOR
KNOCK SENSOR > INSPECTION
for Preparation
Click here
1. INSPECT KNOCK SENSOR
Using an ohmmeter, measure the resistance between terminals.
Resistance:
120 to 280 kΩ at 20°C (68°F)
HINT:
If the resistance is not as specified, replace the sensor.