FUEL PUMP > INSTALLATION |
| 1. INSTALL FUEL SUCTION WITH PUMP & GAGE TUBE ASSEMBLY |
![]() |
Install a new gasket onto the fuel tank.
Set the fuel suction with pump & gage tube assembly to the fuel tank.
Fit the spline of the fuel suction with pump & gage tube assembly into the keyway of the fuel tank.
![]() |
Install the retainer.
Using a new retainer, align the mark on the retainer with the screw-thread starting point of the fuel tank.
While holding the fuel suction with pump & gage tube assembly, tighten the retainer one complete turn by hand.
![]() |
Using SST, tighten the retainer one more complete turn, and position the mark on the retainer into range A of the fuel tank.