1. INSPECT HORN RELAY ASSEMBLY


    B016200E24
  1. Remove the horn relay from the instrument panel junction block assembly.

  1. Inspect the horn relay continuity.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    Always
    Below 1 Ω
    3 - 5
    Apply B+ between terminals 1 and 2

    If the result is not as specified, replace the relay assembly.