DTC    11    Room Temperature Sensor Circuit

for Preparation Click here


DESCRIPTION

This sensor detects the temperature inside the cabin and sends appropriate signals to the A/C amplifier.

DTC No.
Detection Item
Trouble Area
11
Open or short in room temperature sensor circuit
  1. Cooler thermistor (Room temperature sensor)
  2. Harness or connector between cooler thermistor (room temperature sensor) and A/C amplifier
  3. A/C amplifier

WIRING DIAGRAM


I045740E01


INSPECTION PROCEDURE

1.INSPECT AIR CONDITIONING AMPLIFIER (TR, SG)


    I033523E01
  1. Remove the A/C amplifier with the connectors still connected.

  1. Turn the ignition switch ON.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    (Symbols)
    Condition
    Specified Condition
    A16-15 (TR) - A16-6 (SG)
    Ignition switch ON at 25°C (77°F)
    1.8 to 2.2 V
    A16-15 (TR) - A16-6 (SG)
    Ignition switch ON at 40°C (104°F)
    1.2 to 1.6 V

    HINT:
    As the temperature increases, the voltage decreases.



OK
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE
NG


2.INSPECT COOLER THERMISTOR (ROOM TEMPERATURE SENSOR)


    I030111
  1. Remove the cooler thermistor (room temp. sensor).



    I041430E08
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    A19-1 - A19-2
    10°C (50°F)
    3.00 to 3.73 kΩ
    A19-1 - A19-2
    15°C (59°F)
    2.45 to 2.88 kΩ
    A19-1 - A19-2
    20°C (68°F)
    1.95 to 2.30 kΩ
    A19-1 - A19-2
    25°C (77°F)
    1.60 to 1.80 kΩ
    A19-1 - A19-2
    30°C (86°F)
    1.28 to 1.47 kΩ
    A19-1 - A19-2
    35°C (95°F)
    1.00 to 1.22 kΩ
    A19-1 - A19-2
    40°C (104°F)
    0.80 to 1.00 kΩ
    A19-1 - A19-2
    45°C (113°F)
    0.65 to 0.85 kΩ
    A19-1 - A19-2
    50°C (122°F)
    0.50 to 0.70 kΩ
    A19-1 - A19-2
    55°C (131°F)
    0.44 to 0.60 kΩ
    A19-1 - A19-2
    60°C (140°F)
    0.36 to 0.50 kΩ

    NOTICE:
    1. Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
    2. When measuring the sensor temperature, it must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (see the graph).



NG
REPLACE COOLER THERMISTOR (ROOM TEMPERATURE SENSOR)
OK


3.CHECK HARNESS AND CONNECTOR (COOLER THERMISTOR (ROOM TEMPERATURE SENSOR) - A/C AMPLIFIER)
  1. Check for open and short circuit in the harness and the connector between the cooler thermistor (room temp. sensor) and the A/C amplifier (Click here).



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4.CHECK DTC
  1. Start up the DTC check mode.

  1. Check that DTC 11 is not output again.

    Result:

    Result
    Proceed to
    DTC 11 is output.
    A
    DTC 11 is not output.
    B



B
SYSTEM IS OK
A

REPLACE AIR CONDITIONING AMPLIFIER