DTC 11 Room Temperature Sensor Circuit |
| DTC No. | Detection Item | Trouble Area |
| 11 | Open or short in room temperature sensor circuit |
|

| 1.INSPECT AIR CONDITIONING AMPLIFIER (TR, SG) |
![]() |
Remove the A/C amplifier with the connectors still connected.
Turn the ignition switch ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection (Symbols) | Condition | Specified Condition |
| A16-15 (TR) - A16-6 (SG) | Ignition switch ON at 25°C (77°F) | 1.8 to 2.2 V |
| A16-15 (TR) - A16-6 (SG) | Ignition switch ON at 40°C (104°F) | 1.2 to 1.6 V |
|
| ||||
| NG | |
| 2.INSPECT COOLER THERMISTOR (ROOM TEMPERATURE SENSOR) |
![]() |
Remove the cooler thermistor (room temp. sensor).
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A19-1 - A19-2 | 10°C (50°F) | 3.00 to 3.73 kΩ |
| A19-1 - A19-2 | 15°C (59°F) | 2.45 to 2.88 kΩ |
| A19-1 - A19-2 | 20°C (68°F) | 1.95 to 2.30 kΩ |
| A19-1 - A19-2 | 25°C (77°F) | 1.60 to 1.80 kΩ |
| A19-1 - A19-2 | 30°C (86°F) | 1.28 to 1.47 kΩ |
| A19-1 - A19-2 | 35°C (95°F) | 1.00 to 1.22 kΩ |
| A19-1 - A19-2 | 40°C (104°F) | 0.80 to 1.00 kΩ |
| A19-1 - A19-2 | 45°C (113°F) | 0.65 to 0.85 kΩ |
| A19-1 - A19-2 | 50°C (122°F) | 0.50 to 0.70 kΩ |
| A19-1 - A19-2 | 55°C (131°F) | 0.44 to 0.60 kΩ |
| A19-1 - A19-2 | 60°C (140°F) | 0.36 to 0.50 kΩ |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (COOLER THERMISTOR (ROOM TEMPERATURE SENSOR) - A/C AMPLIFIER) |
Check for open and short circuit in the harness and the connector between the cooler thermistor (room temp. sensor) and the A/C amplifier (Click here).
|
| ||||
| OK | |
| 4.CHECK DTC |
Start up the DTC check mode.
Check that DTC 11 is not output again.
| Result | Proceed to |
| DTC 11 is output. | A |
| DTC 11 is not output. | B |
|
| ||||
| A | ||
| ||