DTC 13 Evaporator Temperature Sensor Circuit |
| DTC No. | Detection Item | Trouble Area |
| 13 | Open or short in evaporator temperature sensor circuit |
|

| 1.INSPECT AIR CONDITIONING AMPLIFIER (TE, SG) |
![]() |
Remove the A/C amplifier with the connectors still connected.
Turn the ignition switch ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection (Symbols) | Condition | Specified Condition |
| A16-24 (TE) - A16-6 (SG) | Ignition switch ON at 0°C (32°F) | 2.0 to 2.4 V |
| A16-24 (TE) - A16-6 (SG) | Ignition switch ON at 15°C (59°F) | 1.4 to 1.8 V |
|
| ||||
| NG | |
| 2.INSPECT COOLER THERMISTOR NO. 1 (EVAPORATOR TEMPERATURE SENSOR) |
![]() |
Remove the cooler thermistor No. 1 (evaporator temp. sensor).
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A18-1 - A18-2 | -10°C (14°F) | 7.30 to 9.10 kΩ |
| A18-1 - A18-2 | -5°C (23°F) | 5.65 to 6.95 kΩ |
| A18-1 - A18-2 | 0°C (32°F) | 4.40 to 5.35 kΩ |
| A18-1 - A18-2 | 5°C (41°F) | 3.40 to 4.15 kΩ |
| A18-1 - A18-2 | 10°C (50°F) | 2.70 to 3.25 kΩ |
| A18-1 - A18-2 | 15°C (59°F) | 2.14 to 2.58 kΩ |
| A18-1 - A18-2 | 20°C (68°F) | 1.71 to 2.05 kΩ |
| A18-1 - A18-2 | 25°C (77°F) | 1.38 to 1.64 kΩ |
| A18-1 - A18-2 | 30°C (86°F) | 1.11 to 1.32 kΩ |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (COOLER THERMISTOR NO. 1 - A/C AMPLIFIER) |
Check for open and short in the harness and the connector between the cooler thermistor No. 1 (evaporator temp. sensor) and the A/C amplifier (Click here).
|
| ||||
| OK | |
| 4.CHECK DTC |
Start up the DTC check mode.
Check that DTC 13 is not output again.
| Result | Proceed to |
| DTC 13 is output. | A |
| DTC 13 is not output. | B |
|
| ||||
| A | ||
| ||