CONDENSER > INSTALLATION |
| 1. INSTALL COOLER CONDENSER CUSHION NO. 1 |
![]() |
Install the cooler condenser cushion No. 1 with the 4 bolts.
| 2. INSTALL COOLER CONDENSER CUSHION NO. 2 |
![]() |
Install the cooler condenser cushion No. 2 with the 4 bolts and nut.
![]() |
Install the cooler condenser bracket No. 1 with the nut.
| 3. INSTALL AIR CONDITIONING TUBE ASSEMBLY |
Remove the attached vinyl tape from the tube and connecting part of the cooler condenser assembly.
Sufficiently apply compressor oil to a new O-ring and fitting surface of the pipe joint.
Install the O-ring on the air conditioning tube assembly.
![]() |
Connect the air conditioning tube assembly on the cooler condenser assembly with the bolt.
| 4. INSTALL DISCHARGE HOSE SUB-ASSEMBLY |
Remove the attached vinyl tape from the tube and connecting part of the cooler condenser assembly.
Sufficiently apply compressor oil to a new O-ring and fitting surface of the pipe joint.
![]() |
Install the O-ring on the discharge hose sub-assembly.
Connect the discharge hose sub-assembly on the cooler condenser assembly with the bolt.
| 5. CHARGE REFRIGERANT |
Perform vacuum purging using a vacuum pump.
Charge refrigerant HFC-134a (R134a).

| 6. WARM UP ENGINE |
Warm up the engine at less than 1,850 rpm for 2 minutes or more after charging the refrigerant.
| 7. INSPECT LEAKAGE OF REFRIGERANT |
After recharging the refrigerant gas, check for refrigerant gas leakage using a halogen leak detector.
Perform the operation under the following conditions:
![]() |
Using a gas leak detector, check the refrigerant line for leakage.
If a gas leak is not detected on the drain hose, remove the blower motor control (blower resistor) from the cooling unit. Insert the gas leak detector sensor into the unit and perform the test.
Disconnect the connector and leave the pressure switch on for approximately 20 minutes. Bring the gas leak detector close to the pressure switch and perform the test.