Home › ENGINE · 2UZ-FE › EMISSION CONTROL › HEATED OXYGEN SENSOR

HEATED OXYGEN SENSOR > INSPECTION

for Preparation Click here



1. INSPECT HEATED OXYGEN SENSOR (for Sensor 2)


    A062378E43
  1. Using an ohmmeter, measure resistance between the terminals.

    Resistance:
    Terminal No.
    Resistance
    1 (HT) ←→ 2 (+B)
    11 to 16 Ω at 20°C (68°F)
    1 (HT) ←→ 4 (E1)
    10 kΩ or higher