AIR SWITCHING VALVE > ON-VEHICLE INSPECTION |
| 1. INSPECT NO. 2 AIR SWITCHING VALVE |
![]() |
Disconnect the vacuum hose from the VSV for the air injection system (Procedure "A").
Apply vacuum (30 kPa (306 gf/cm2, 4.35 psi)) to the vacuum hose, and check that the vacuum does not decrease (Procedure "B").
If operation is not as specified, replace the No. 2 air switching valve.
![]() |
Release the vacuum, and check that an operation sound is emitted from the No. 2 air switching valve (Procedure "C").
If operation is not as specified, replace the No. 2 air switching valve.
Perform procedures "A" to "C" for the other No. 2 air switching valve.