CAN COMMUNICATION SYSTEM > CAN Bus Line |

| 1.CHECK CAN BUS LINE (MAIN BUS LINE FOR DISCONNECTION, BUS LINES FOR SHORT CIRCUIT) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester connection | Condition | Specified value | Result |
| D1-6 (CANH) - D1-14 (CANL) |
| 54 to 69 Ω | OK |
| D1-6 (CANH) - D1-14 (CANL) |
| 69 Ω or higher | NG-A |
| D1-6 (CANH) - D1-14 (CANL) |
| Below 54 Ω | NG-B |
|
| ||||
|
| ||||
| OK | |
| 2.CHECK CAN BUS LINE FOR SHORT TO +B |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester connection | Condition | Specified value |
| D1-6 (CANH) - D1-16 (BAT) |
| 1 MΩ or higher |
| D1-14 (CANL) - D1-16 (BAT) |
| 1 MΩ or higher |
|
| ||||
| OK | |
| 3.CHECK CAN BUS LINE FOR SHORT TO GND |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester connection | Condition | Specified value |
| D1-4 (CG) - D1-6 (CANH) |
| 3 kΩ or higher |
| D1-4 (CG) - D1-14 (CANL) |
| 3 kΩ or higher |
|
| ||||
| OK | ||
| ||