Home › COMMUNICATION SYSTEM › CAN COMMUNICATION › CAN COMMUNICATION SYSTEM

CAN COMMUNICATION SYSTEM > Can Main Bus Line for Disconnection

for Preparation Click here


DESCRIPTION

The CAN main bus line and DLC3 sub bus line may have a disconnection when the resistance between terminals 6 (CANH) and 14 (CANL) of the DLC3 is more than 69 Ω.

Symptom
Trouble Area
Resistance between terminals 6 (CANH) and 14 (CANL) of the DLC3 is more than 69 Ω.
  1. CAN main bus line
  2. ECM
  3. CAN J/C

WIRING DIAGRAM


G036693E01


INSPECTION PROCEDURE

1.CHECK DLC3


    G026206E73
  1. Measure the resistance according to the value(s) in the table below.

    Result:
    Tester connection
    Condition
    Specified value
    Result
    D1-6 (CANH) - D1-14 (CANL)
    1. IG switch OFF
    2. Stop light switch OFF
    108 to 132 Ω
    A
    D1-6 (CANH) - D1-14 (CANL)
    1. IG switch OFF
    2. Stop light switch OFF
    132 Ω or higher
    B

    NOTICE:
    When the measured value is 132 Ω or more and a CAN communication system diagnostic code is output, there may be a fault other than a disconnection of the DLC3 sub bus line. For that reason, troubleshooting should be performed again from "How to Proceed with Troubleshooting" after repairing the trouble area.



B
REPAIR OR REPLACE DLC3 SUB BUS LINE OR CONNECTOR (CAN-H, CAN-L)
A


2.CHECK CAN MAIN BUS LINE FOR DISCONNECTION (ECM - CAN J/C)


    G038051E01
  1. Disconnect the connector (E7) from the ECM.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester connection
    Condition
    Specified value
    E7-33 (CANH) - E7-34 (CANL)
    1. IG switch OFF
    2. Stop light switch OFF
    108 to 132 Ω



OK
REPLACE ECM
NG


3.CHECK CAN J/C


    G031933E32
  1. Disconnect the CAN main bus line connector (J51) from the CAN J/C.

    NOTICE:
    1. Before disconnecting the connector, make a note of where it is connected.
    2. Reconnect the connector to its original position.



    G026370E04
  1. Measure the resistance according to the value in the table below.

    Standard resistance:
    Between the terminals where the connector (J51) was connected
    Condition
    Specified value
    CANH - CANL
    1. IG switch OFF
    2. Stop light switch OFF
    108 to 132 Ω



NG
REPLACE CAN J/C
OK

REPAIR OR REPLACE CAN MAIN BUS LINE OR CONNECTOR (CAN J/C - ECM)