BACK DOOR CLOSER SYSTEM > TERMINALS OF ECU |
| CHECK MULTIPLEX NETWORK DOOR ECU BACK (BACK DOOR ECU) |

Disconnect the B8 and B9 ECU connectors, and check the voltage or continuity of each terminal of the wire harness side connectors.
| Symbols (Terminal No.) | Wiring Color | Condition | Specified Condition |
| BDR (B8-4) - Body Ground | L - - | Constant | 10 to 14 V |
| BECU (B8-5) - Body Ground | L-R - - | Constant | 10 to 14 V |
| GND (B8-3) - Body Ground | W-B - - | Constant | Continuity |
| SIG (B8-6) - Body Ground | B - - | No key inserted in ignition key cylinder → Key inserted | No continuity → Continuity |
| HSW+ (B9-10) - Body Ground | V-W - - | Back door opener switch OFF → ON | No continuity → Continuity |
| HSW- (B9-22) - Body Ground | LG-R - - | ||
| HALF (B9-6) - Body Ground | R-G - - | Back door OPEN → CLOSED | Continuity → No continuity |
| LSE (B9-21) - Body Ground | B-R - - | Constant | Continuity |
Reconnect the connectors, and check the voltage of each terminal of the connectors.
| Symbols (Terminal No.) | Wiring Color | Condition | Specified Condition |
| ACT+ (B9-15) - Body Ground | L-B - - | Back door OPEN → NOT COMPLETELY CLOSED → Motor in normal rotation (Right turn) → Motor in revers rotation (Left turn) → Operation completed (Back door CLOSED) | Below 1 V → Below 1 V → 10 to14 V → Below 1 V → Below 1 V |
| ACT- (B9-14) - Body Ground | L-R - - | Back door OPEN → NOT COMPLETELY CLOSED → Motor in normal rotation (Right turn) → Motor in revers rotation (Left turn) → Operation completed (Back door CLOSED) | Below 1 V → Below 1 V → Below 1 V → 10 to 14 V → Below 1 V |
| FULL (B9-7) - Body Ground | G-Y - - | Back door CLOSED → OPEN | 10 to 14 V → Below 1 V |
| POS (B9-8) - Body Ground | BR-W - - | Back door OPEN → Closer in operation → CLOSED | Below 1 V → 10 to 14 V → Below 1 V |