Home › ENGINE · 1GR-FE › IGNITION › IGNITION SYSTEM

IGNITION SYSTEM > INSPECTION

for Preparation Click here



1. INSPECT CRANKSHAFT POSITION SENSOR
  1. Using an ohmmeter, measure the resistance between the terminals.

    Resistance:
    Cold:
    1,630 to 2,740 Ω
    Hot:
    2,065 to 3,225 Ω

    NOTICE: