DTC B1628/29 Roll Over Cut Off Indicator Malfunction |
| DTC No. | DTC Detecting Condition | Trouble Area |
| B1628/29 |
|
|

| 1.CHECK RSCA OFF INDICATOR CONDITION |
Turn the ignition switch to the ON position, and push the RSCA OFF switch for 2 seconds.
Check the RSCA OFF indicator condition according to the table below.
| Proceed to | Condition |
| A | RSCA OFF indicator dose not come on (remains off) when the RSCA OFF switch is operated. |
| B | RSCA OFF indicator remains on when the RSCA OFF switch is not operated. |
|
| ||||
| A | |
| 2.CHECK COMBINATION METER ASSEMBLY (SOURCE VOLTAGE) |
![]() |
Turn the ignition switch to the LOCK position.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Remove the combination meter assembly (Click here).
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to the ON position.
Measure the voltage according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| C8-10 - Body ground | Ignition switch ON | 10 to 14 V |
|
| ||||
| OK | |
| 3.CHECK INSTRUMENT PANEL WIRE (CENTER AIRBAG SENSOR ASSEMBLY - COMBINATION METER ASSEMBLY) |
![]() |
Turn the ignition switch to the LOCK position.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect the connector from the center airbag sensor assembly.
Measure the resistance according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| A32-6 (RMIL) - C8-10 | Always | Below 1 Ω |
|
| ||||
| OK | |
| 4.CHECK INSTRUMENT PANEL WIRE (SHORT TO B+) |
![]() |
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to the ON position.
Measure the voltage according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| C8-10 - Body ground | Ignition switch ON | Below 1 V |
|
| ||||
| OK | |
| 5.CHECK CENTER AIRBAG SENSOR ASSEMBLY |
![]() |
Turn the ignition switch to the LOCK position.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Connect the connector to the center airbag sensor assembly.
Install the combination meter assembly (Click here).
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to the ON position, and wait for at least 60 seconds.
Clear the DTCs stored in memory (Click here).
Turn the ignition switch to the LOCK position.
Turn the ignition switch to the ON position, and wait for at least 60 seconds.
Check the DTCs (Click here).
|
| ||||
| OK | ||
| ||
| 6.CHECK RSCA OFF INDICATOR OPERATION |
Turn the ignition switch to the LOCK position.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect the connector from the center airbag sensor assembly.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to the ON position.
Check the RSCA OFF indicator condition.
|
| ||||
| NG | |
| 7.CHECK INSTRUMENT PANEL WIRE (SHORT TO GROUND) |
![]() |
Turn the ignition switch to the LOCK position.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Remove the combination meter assembly (Click here).
Measure the resistance according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| C8-10 - Body ground | Always | 1 MΩ or higher |
|
| ||||
| OK | ||
| ||