WATER PUMP > REMOVAL |
| 1. REMOVE NO. 1 ENGINE UNDER COVER SUB-ASSEMBLY |
Remove the 4 bolts and engine under cover.
| 2. DRAIN ENGINE COOLANT |
![]() |
Remove the service hole cover from the engine under cover.
Install a vinyl hose onto the drain on the radiator side.
Fix the vinyl hose with tape.
![]() |
Loosen the 3 drain plugs on the engine and radiator, and drain the coolant.
Remove the radiator cap.
Drain the coolant from the reservoir tank.
Tighten the 3 drain plugs.
Remove the vinyl hose from the radiator.
| 3. REMOVE V-BANK COVER |
![]() |
Remove the 2 nuts, then remove the V-bank cover.
| 4. REMOVE RADIATOR SUPPORT SEAL UPPER |
Remove the 11 clips and radiator support seal upper.
| 5. LOOSEN FAN WITH FLUID COUPLING |
![]() |
Loosen the 4 fluid coupling bolts.
| 6. REMOVE FAN AND GENERATOR V BELT |
![]() |
While releasing the belt tension by turning the belt tensioner counterclockwise, remove the V-ribbed belt from the belt tensioner.
| 7. REMOVE FAN WITH FLUID COUPLING |
![]() |
Unfasten the hose clamp, and then separate the 2 oil cooler hoses from the fan shroud.
Disconnect the radiator reserve tank hose.
Remove the 2 fan shroud bolts and radiator reserve tank bolt.
Remove the 4 fluid coupling nuts, and then remove the fan with fluid coupling and fan shroud together.
Remove the fan pulley.
| 8. DISCONNECT VENTILATION HOSE NO.2 |
| 9. REMOVE AIR CLEANER ASSEMBLY |
| 10. REMOVE WATER INLET |
![]() |
Disconnect the 2 oil cooler hoses (with oil cooler).
![]() |
Disconnect the 2 radiator hoses.
![]() |
Disconnect the 5 water by-pass hoses.
![]() |
Remove the 5 bolts and water inlet.
Remove the O-ring from the water outlet pipe.
Remove the gasket from the water pump.
| 11. REMOVE NO. 2 IDLER PULLEY SUB-ASSEMBLY |
![]() |
Remove the 2 bolts and 2 idler pulleys.
| 12. REMOVE GENERATOR ASSEMBLY |
![]() |
Disconnect the wire harness.
Remove the bolt and wire harness stay.
Disconnect the connector from the generator assembly.
Remove the terminal cap and nut.
Disconnect the wire harness from the terminal B.
![]() |
Remove the 2 bolts and wire harness clamp bracket from the generator assembly.
![]() |
Remove the 2 bolts and generator assembly.
| 13. SEPARATE COOLER COMPRESSOR ASSEMBLY |
![]() |
Remove the bolt and separate the suction hose sub-assembly.
Disconnect the cooler compressor assembly connector.
Remove the 4 bolts and separate cooler compressor assembly from the V-ribbed belt tensioner assembly.
| 14. REMOVE V-RIBBED BELT TENSIONER ASSEMBLY |
![]() |
Remove the 5 bolts and V-ribbed belt tensioner.
| 15. REMOVE WATER PUMP ASSEMBLY |
![]() |
Remove the 17 bolts, water pump and gasket.