Home › ENGINE ยท 2UZ-FE › STARTING › ACC CUT RELAY

ACC CUT RELAY > INSPECTION

for Preparation Click here



1. INSPECT ACC CUT RELAY


    A030519
  1. Continuity inspection.

    1. Using an ohmmeter, check for continuity between each terminal.

      Specified condition:
      Between Terminals
      Specified Condition
      1 - 2
      Continuity
      3 - 5
      No continuity

    2. Using an ohmmeter, check for continuity between terminals 3 and 5 when voltage is applied across terminals 1 and 2.

      Specified condition:
      Continuity